Print quality—residual image
Service tip: Install a new print cartridge, if available, before doing this service check.
Residual image can be caused by the photoconductor, cleaning blade, and other parts
inside the print cartridge.
Step
Questions / actions
1
Check the condition of the imaging unit using
the customer menus (administrative menus):
1. At the Ready prompt, press Menu (
2. Select Supplies Menu, and press Select
(
).
3. Select Imaging Kit, and press Select (
Does the display indicate OK?
2
Measure the distance from the original image
to the same point on the residual image.
Is the distance 43.9 mm?
3
Is the distance between the original image and
the residual image 94.2 mm?
4
Run the Menu Setting Page twice to clear any
debris.
To print a menu settings page:
1. press Menu (
2. Select Reports from the Admin Menu, and
press Select (
3. Select Menu Settings, and press
Select (
Is there still any toner contamination on the
fuser assembly?
Y112730-2
) on the operator panel.
).
).
Yes
Go to step 2.
).
).
Replace the developer
corresponding to the color of
the image. See
"Developer
unit removal" on
page
4-42.
Replace the
photoconductor. See
"Developer unit removal"
on page
4-42.
Replace the fuser. See
"Fuser assembly
removal" on page
ABCDE
ABCDE
ABCDE
Replace the imaging unit or
the photoconductor unit.
See
"Imaging unit (IU)
removal" on page
Replace the imaging unit or
the photoconductor unit.
See
"Imaging unit (IU)
removal" on page
Contact your next level of
support.
4-25.
Diagnostic information
No
4-40.
4-40.
2-55