Showing Redundancy Status; Switching Over Redundant Modules - HP procurve 8100fl series Management And Configuration Manual

Hide thumbs Also See for procurve 8100fl series:
Table of Contents

Advertisement

File and System Management
Managing System Devices and Software
N o t e
3-12
You can gracefully stop a management module or fabric module and cause the
redundant module to take over by using the following command in Privileged
Exec mode:
ProCurve#halt <module>
Alternatively, you can power down the fabric module slot by issuing the
following command:
ProCurve#power down <fabric-module slot>
When you power down a slot, the system turns power off to that slot and will
keep power off until you enter the power up command. This is true even if you
reboot the system.

Showing Redundancy Status

To view the active or standby status of redundant management or fabric
modules, enter the show redundancy command. This displays the following
types of information:
ProCurve#show redundancy
Slot
Module-Type
-----------------------------------------------------------
MM-A
Management Module
MM-B
Management Module
FM-A
Fabric Module
MM-B
Management Module

Switching Over Redundant Modules

To switch the system to the backup management or fabric module, enter the
redundancy switchover command at the Privileged Exec level of the CLI:
ProCurve#redundancy switchover {management-module | fabric-
module} [manual | force | lock | clear]]
Model
State
fl Mgmt
active
No module
standby
8108fl Fabric
active
No module
standby
Switch
auto
auto
auto
auto