Akai MPC User Manual page 186

Hide thumbs Also See for MPC:
Table of Contents

Advertisement

Hardware:
To zoom in and out of the waveform, do one of the following:
Press and hold Shift and use the left and right Cursor Buttons.
Use Q-Link Knob Q4.
Use Q-Link Knob Q8 to scroll the Waveform Display.
To adjust the start point of the sample, use Q-Link Knobs Q13, Q9, Q5, or Q1. The smaller the Q-
Link Knob number, the more precise the adjustment of the start point.
To adjust the end point of the sample, use Q-Link Knobs Q14, Q10, Q6, or Q2. The smaller the Q-
Link Knob number, the more precise the adjustment of the end point.
To adjust the loop point of the sample, use Q-Link Knobs Q15, Q11, Q7, or Q3. The smaller the Q-
Link Knob number, the more precise the adjustment of the loop point.
Tips:
Remember that the loop start point cannot be placed before the start point of a sample.
Click the waveform and hold the mouse button to play the edited sample.
Click the sample timeline to switch between Time (in seconds and milliseconds) and Samples.