Sharp MX-M200D Service Manual page 56

Hide thumbs Also See for MX-M200D:
Table of Contents

Advertisement

Main
Sub
code
code
41
03
Document size detection photo sensor light receiving/detection level check
When this simulation is executed, the light receiving level of the document detection photo sensor is
displayed. (Real time display)
The values in parentheses of sensor 4 and 5 are the threshold values of adjustment at SIM41-04. Since
sensors 1 and 3 are not provide with the threshold value of detection at SIM41-04, "0" is always displayed.
Sim41-3 PD SENSOR
OCS
1[000] 200
3[000] 200
5[050] 200
04
Detection level adjustment when the document size is settled (15 degrees - 20 degrees)
Set the OC cover to the document size settled state (15 degrees - 20 degrees), and press [OK] key.
1 Initial window
Sim41-4 20 SENSOR
PRESS OK KEY EXEC
The detection level under the document size settled state is saved in the EEPROM, and the value is
displayed in [ ].
* The document size settled state means the point when the open/close sensor (OCSW) is switched from
ON (highlighted) to OFF (normal display).
42
01
Developing counter clear
Used to clear the developing counter. When this simulation is executed, the confirmation window is
displayed to confirm to clear or not. To clear, press [OK] key or [START] key. Not to clear, press
[INTERRUPT] key or [CA] key to exit the simulation mode.
Sim42-1 COUNTER CLR
DEVELOPER COUNTER
CLEAR
ARE YOU SURE? EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
43
01
Fusing temperature setting (Normal copy)
Used to set the fusing temperature in normal copy.
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the set value is increased by 5°C from the current display temperature.
Every time when [ ] key is pressed, the set value is decreased by 5°C from the current display temperature.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Setting can be made in the range of 160°C to 200°C in the increment of 5°C.
Sim43-1 FUSER TEMP.
1:FUSER TEMP
[160- 200]
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
2[000] 200
4[050] 200
2 After-execution window
Sim41-4 20 SENSOR
OCS
1[000] 163
3[001] 167
5[197] 179
0 : 160 C
1 : 165 C
170
2 : 170 C
3 : 175 C
4 : 180 C
170
5 : 185 C
6 : 190 C
7 : 195 C
8 : 200 C
MX-M200D SIMULATIONS 7-27
Contents
2[000] 148
4[0C6] 180
Remark
Default:
2