Sharp MX-M283N Installation Manual

Sharp MX-M283N Installation Manual

Digital multifunctional system
Hide thumbs Also See for MX-M283N:

Advertisement

1
: '10/Jun/18
CONFIGURATION
[1]
MX-M283N/M363N/M363U/
M453N/M453U/M503N/M503U/
M282N/M362N/M452N/M502N . . . . 1-1
1
[2]
MX-DEX8/DEX9 . . . . . . . . . . . . . . . . 2-1
[3]
MX-LCX1 . . . . . . . . . . . . . . . . . . . . . 3-1
[4]
MX-FNX9 . . . . . . . . . . . . . . . . . . . . . 4-1
[5]
MX-PNX1 . . . . . . . . . . . . . . . . . . . . . 5-1
[6]
MX-RBX3 . . . . . . . . . . . . . . . . . . . . . 6-1
[7]
MX-FN10 . . . . . . . . . . . . . . . . . . . . . 7-1
[8]
MX-PNX5A/B/C/D . . . . . . . . . . . . . . 8-1
[9]
MX-FN11 . . . . . . . . . . . . . . . . . . . . . 9-1
[10] MX-PNX6A/B/C/D . . . . . . . . . . . . . 10-1
[11] MX-TRX2 . . . . . . . . . . . . . . . . . . . . 11-1
[12] MX-FXX2 . . . . . . . . . . . . . . . . . . . . 12-1
[13] AR-SU1 . . . . . . . . . . . . . . . . . . . . . 13-1
[14] MX-PB10 . . . . . . . . . . . . . . . . . . . . 14-1
[15] MX-PB11 . . . . . . . . . . . . . . . . . . . . 15-1
Parts marked with "
" are important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
INSTALLATION MANUAL
DIGITAL MULTIFUNCTIONAL SYSTEM
MODEL
CONTENTS
[16] MX-FWX1. . . . . . . . . . . . . . . . . . . . 16-1
[17] MX-EBX3 . . . . . . . . . . . . . . . . . . . . 17-1
[18] MX-PKX1 . . . . . . . . . . . . . . . . . . . . 18-1
[19] MX-PUX1 . . . . . . . . . . . . . . . . . . . . 19-1
[20] MX-SMX3. . . . . . . . . . . . . . . . . . . . 20-1
[21] AR-PF1 . . . . . . . . . . . . . . . . . . . . . 21-1
[22] MX-FR14U/FR14/FR15U/FR15/
[23] MX-KBX2 . . . . . . . . . . . . . . . . . . . . 23-1
[24] MX-AMX1. . . . . . . . . . . . . . . . . . . . 24-1
[25] MX-AMX2. . . . . . . . . . . . . . . . . . . . 25-1
[26] MX-AMX3. . . . . . . . . . . . . . . . . . . . 26-1
[27] Dehumidifying heater . . . . . . . . . . . 27-1
[28] MX-RP11 . . . . . . . . . . . . . . . . . . . . 28-1
[29] MX-PC11/XB13

SHARP CORPORATION

CODE: 00ZMXM503/I3E
MX-M283N
MX-M363N/U
MX-M453N/U
MX-M503N/U
MX-M282N/M362N
MX-M452N/M502N
FR24U . . . . . . . . . . . . . . . . . . . . . . 22-1
* Refer to the MX-PC11
(00ZMXPC11/A1J) service manual
This document has been published to be used
for after sales service only.
The contents are subject to change without notice.
1
1
1

Advertisement

Table of Contents
loading

Summary of Contents for Sharp MX-M283N

  • Page 1: Sharp Corporation

    : '10/Jun/18 INSTALLATION MANUAL CODE: 00ZMXM503/I3E DIGITAL MULTIFUNCTIONAL SYSTEM MX-M283N MX-M363N/U MX-M453N/U MX-M503N/U MX-M282N/M362N MX-M452N/M502N MODEL CONTENTS CONFIGURATION [16] MX-FWX1....16-1 MX-M283N/M363N/M363U/ [17] MX-EBX3 .
  • Page 2: Table Of Contents

    [15] MX-PB11 Unpacking ......15-1 MX-M283N/M363N/M363U/M453N/M453U/M503N/ M503U/M282N/M362N/M452N/M502N Installation ......15-1 Installing (use) conditions .
  • Page 3: Configuration

    MX-M282N/M362N/M452N/M502N REVERSING SINGLE DOCUMENT COVER PASS FEEDER MX-VRX1 MX-RP11 Paper exit system STAPLE CARTRIDGE MX-SCX1 DIGITAL MULTIFUNCTIONAL SYSTEM DIGITAL MULTIFUNCTIONAL SYSTEM MX-M283N/M363N/M453N/M503N MX-M363U/M453U/M503U PAPER PASS UNIT MX-RBX3 STAPLE CA RTRIDGE AR-SC3 (For saddle) PUNCH MODULE SADDLE STITCH FINISHER MX-PNX5 MX-FN10...
  • Page 4: Main Unit Configuration

    SHARPDESK DATA SECURITY KIT 10 LICENSE KIT MX-FR24U MX-US10 Memory EXPANSION MEMORY BOARD MX-SMX3 2. Main unit configuration MX-M363N/MX-M453N/ MX-M363U/MX-M453U/ MX-M282N/MX-M362N/ MX-M283N MX-M503N MX-M503U MX-M452N/MX-M502N Copier PCL printer OPT*1 PS printer OPT*1 OPT*1 OPT*1 OPT*1 Main body LCD COLOR WVGA 8.5"...
  • Page 5: Mx-Ebx3

    *2: Standard for North America. *3: Memory expansion are required. *4: The printer expansion kit with hard drive (MX-PB11) is required. *5: MX-M283N includes this as standard equipment. Other models of MX-M283N includes DSPF as standard equipment. MX-M503N CONFIGURATION - iii...
  • Page 6: Installing (Use) Conditions

    Use of a step-up transformer is also available. In this case, the Humidity: 20 to 85% RH capacity must be great enough for the max. power consumption of the machine. Atmospheric pressure: 590 to 1013hPa (altitude: 0 to 2000 m) MX-M503N MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N 1 – 1...
  • Page 7 Avoid installation near a machine which produces vibrations. If vibrations are applied to the copier machine, copy images may be deflected and a trouble may be caused. • When repairing or replacing an electronic part, perform the procedure on an anti-static mat. MX-M503N MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N 1 – 2...
  • Page 8: Transit And Delivery

    Since the hard disk drive is built in the machine, use care not to exert vibrations or shocks to the machine when in transit. B. Delivery Remove the packing materials prior to installation in the office envi- ronment. MX-M503N MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N 1 – 3...
  • Page 9 Parts name Quantity (2) Scanner (2/3 mirror unit) lock release Paper exit full detection actuator Paper holding plate unit Remove the optical unit fixing screw, and remove the note Operation manual label. Operation manual pocket MX-M503N MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N 1 – 4...
  • Page 10 Attach the DV cover to the machine. * Check to confirm that the pawl is securely engaged. Insert the developing unit into the machine, and fix it with the blue screw. Install the waste toner box. MX-M503N MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N 1 – 5...
  • Page 11 SIM 25-2 is performed at any other time. D. Install toner cartridge Shake the toner cartridge several times. Install the paper fixing sheet and paper fixture to the paper fix- ture HCT. MX-M503N MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N 1 – 6...
  • Page 12 Tray Settings" has been enabled in the system settings (adminis- trator), the tray settings (except for the bypass tray) cannot be con- figured. Press the [SYSTEM SETTINGS] key. JOB STATUS PRINT READY DA TA SYSTEM SETTINGS IMAGE SEND LINE DA TA HOME LOGOUT MX-M503N MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N 1 – 7...
  • Page 13 The print density must be changed gradually from the lighter level to the darker level. The density changing direction must not be reversed. Patch 3 is copied. Patch A or B is slightly copied. Patch 1 is not copied. MX-M503N MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N 1 – 8...
  • Page 14: Mx-Trx2

    Note that, if DIP SW1 is set to ON, the machine is set to the Let the user make the password, and use SIM26-78 to set it. CN update mode. NOTE: After completion of option installation, revise all the firm- ware to the latest version. MX-M503N MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N 1 – 9...
  • Page 15: Unpacking

    C. Check the packed items [2] MX-DEX8/DEX9 MX-M503N Service Manual Check that all the items are included in the package. Unpacking A. Removal of the desk unit Names of bundles Quantity Right adjuster Fixing screws (M4 x 8) Installation <Note before installation> * Before starting installation, check to insure that the data lamp on the operation panel does not light up or blink.
  • Page 16 B. Installation of the adjuster Put the main unit on the desk unit. * Use man power of four persons or more to lift the main unit. Install the right adjuster (package part No. 1) to the desk unit. Turn each adjuster to fix the desk unit. * Place the main unit on the desk unit slowly by fitting the external lines.
  • Page 17 Lift the connection plates on the right and left of the main unit Lift the connection plates, and fix them with the fixing screws. front side, and fix them with the fixing screws (package part No. 2). Replace the No. 3 and No. 2 trays to the original positions. Install the connection plate covers.
  • Page 18 D. Release the lock E. Connector connection Pull out each tray. Remove the screw from the back of the main unit. Remove the connector cover. Turn and remove the fixing material, and remove the caution Connect the connector. sheet. Attach the removed fixing material to the position shown in the figure for storage.
  • Page 19 F. Turn on the power of the main unit (Note) By pressing [LEAD] or [OFFSET] button, the following items Insert the power plug of the main unit into the power outlet. can be executed individually. * [LEAD]: Print image lead edge image position adjustment * [OFFSET]: Print image off-center adjustment When [ALL] is selected, both of the above two items are executed simultaneously.
  • Page 20: Unpacking

    [3] MX-LCX1 MX-M503N Service Manual Remove the paper feed desk fixing screw. Unpacking A. Removal of the large capacity tray unit NOTE: Before turning on the power, check to insure that the fixing screw of the tray is removed. If the power is turned on without removing the fixing screw, a trouble may be resulted.
  • Page 21 Open the front cabinet. Disengage the pawl, and remove the right adjuster. Turn OFF the power switch in the front cabinet of the main unit. Disconnect the power plug of the main unit from the power out- Remove the screw cap, and remove the screw. let.
  • Page 22 Insert the temporarily fixed screw B into the key hole in the Check to insure that the height adjustment check rib of the connection unit (package part No. 2), and temporarily fix the large capacity tray unit and the axis line of the mounting plate connection unit.
  • Page 23 In the case of a shift to the right, press the front upper section Connect the connector, and tighten the screw. and fit the height adjustment check rib so that it is in the same line with the axis line of the mounting plate upper. Insert the large capacity tray unit into the main unit.
  • Page 24 a. Side plate size switch Loosen the fixing screw (flat screw 1pc) of the auxiliary guide. Remove four fixing screws (blue screws) which are fixing the Set the mark position ( ) of the auxiliary guide and the cas- upper and the lower sections of the side plate F and the side sette R to the size from A4 to LT, and fix with the fixing screw plate R.
  • Page 25 Slightly push the tray, restore the stopper to the original posi- Loosen the stopper fixing screw (1 pc) on the right lower side tion, and fix the fixing screw. of the tray so that the stopper does not function. Pull out the tray again until it stops. At that time, check to insure that the stopper pawl is engaged with the stopper reception of the large capacity tray unit.
  • Page 26 Slightly push the tray, restore the stopper to the original posi- F side R side tion, and fix the fixing screw. b. Auxiliary guide size switch At that time, check to insure that the stopper pawl is engaged * Since the auxiliary guide setting is not required, fix the auxiliary with the stopper reception of the large capacity tray unit.
  • Page 27 Open the front cabinet. Select a paper feed tray to be adjusted. Turn ON the power switch in the front cabinet of the main unit. Press [EXECUTE] key. Turn ON the power switch on the operation panel. The adjustment pattern is printed out. Set the adjustment pattern on the document table.
  • Page 28 Loosen the stopper fixing screw (1 pc) on the right lower side Slowly insert the tray to the original position. of the tray so that the stopper does not function. Then make a copy to check to insure that there is no more shift.
  • Page 29 B. Removal of the fixing tape and protection [4] MX-FNX9 MX-M503N Service Manual material Remove the fixing tape and protection material. Unpacking A. Removal of the inner finisher C. Check the packed items Check that all the items are included in the package. * When removing the inner finisher, lift it as shown in the table below.
  • Page 30 : '10/Jun/18 Installation C. Installation of the inner finisher Open the front cover. <Note before installation> * Before starting installation, check to insure that the data lamp on the operation panel does not light up or blink. A. Turn off the power of the main unit Turn OFF the power switch on the operation panel.
  • Page 31 Remove the paper exit full detection actuator. Fix the dummy punch unit (package part No. 3) with the fixing screw (package part No. 8). Engage the projection on the main unit frame with the hole in the finisher fixing plate (package part No. 1). Fix the right cover plate with the fixing screw (package part No.
  • Page 32 D. Connector Installation 13) Install the front open/close cover (package part No. 4) to the front rail stay rotating shaft, and fix it with the resin clip (pack- Remove the protection material and fixing tape. age part No. 9). 14) Fix the punch cover (package part No. 5) together with the Remove the screw, and remove the connector cover.
  • Page 33 E. Staple position label attachment F. Turn on the power of the main unit Attach the label to the position indicated in the figure. Insert the power plug of the main unit into the power outlet. [For scanner] (package part No. 11) Second label Corner R end fitting Label attachment...
  • Page 34 [5] MX-PNX1 Installation MX-M503N Service Manual * When the punch unit is installed together with installation of Unpacking the MX-FNX9 (inner finisher), first install the inner finisher, and then install the punch unit. A. Removal of the punch unit <Note before installation> * Before starting installation, check to insure that the data lamp on the operation panel does not light up or blink.
  • Page 35 B. Installation of the punch unit Remove two screws, and remove the front cabinet upper. Open the front cabinet. Open the front cover and slide the inner finisher to the left. Remove the screw, and remove the band and the punch cover. Remove the screw, and remove the dummy punch unit.
  • Page 36 Make positioning with the dove (A) and fix the punch unit with 13) Insert the dust box. the screw which was fixing the dummy punch unit. 14) Install the front cabinet upper part using the two screws removed in step 5). 10) Cut the lid of the punch cover with nippers.
  • Page 37 C. Punch position label attachment D. Turn on the power of the main unit Attach the label to the position indicated in the figure. Insert the power plug of the main unit into the power outlet. [For scanner] (Part No. 13 in the package of the MX-FNX9) Lose the clearance.
  • Page 38 [6] MX-RBX3 MX-M503N C. Check the packed items Service Manual Check that all the items are included in the package. Unpacking A. Removal of the interface pass unit Packed part names Quantity Right cover plate Interface left cabinet Reverse tray Fixing screw A Resin clip Reverse detection actuator...
  • Page 39 : '10/Jun/18 B. Removal of the paper holding plate unit Remove the screws, and remove the paper exit tray. * When removing the paper exit tray, there is no need to Disengage the pawl, and remove the paper holding plate and remove the screws in the section (A).
  • Page 40 Insert the rib of the interface left cabinet (package part No. 2) Remove the front connection cabinet from the front cabinet into the slit on the lower surface of the scanner left cabinet. upper, and attach it to the front cabinet upper C (package part Install the interface left cabinet with the fixing screw A (pack- No.
  • Page 41 [7] MX-FN10 MX-M503N Service Manual Remove the skid and packing cushions. Unpacking A. Removal of the saddle finisher * For removal of the saddle stitch finisher, manpower of two per- sons or more is required. Remove the fixing material, and remove the top case. Remove the packing cushion and bundled items.
  • Page 42: Installation

    Installation B. Removal of the fixing tape and protection material <Note before installation> Remove the fixing tape and protection material. * Make sure that none of the data lamps on the operation panels are lit or flashing before starting the installation work. * Installing the MX-FN10 requires that the option desk (MX-DEX8/ DEX9) and junction unit (MX-RBX3) be installed in advance.
  • Page 43 (1) When the guide pin is not fit with the connection Fix the paper holding A with fixing screws A (package part No. hole in the finisher: Loosen the fixing screw of the adjustment section on the rear side. Adjust the height adjustment screw so that the guide pin is fit with the connection hole in the finisher.
  • Page 44 (2) When the guide pin is fit with the connection hole E. Connection of the main unit and saddle in the finisher: finisher Insert the finisher into the main unit. Check to insure that the Fix the connection plate (package part No. 2) to the paper feed upper and lower clearances between the main unit and the fin- desk with fixing screws B (package part No.
  • Page 45 H. Turn on the power of the main unit Connect the finisher connector with the connector of the main unit, and tighten the screw. Insert the power plug of the main unit into the power outlet. Open the front cabinet. Turn ON the power switch in the front cabinet of the main unit.
  • Page 46: Mx-Pnx5A/B/C/D

    [8] MX-PNX5A/B/C/D MX-M503N Service Manual Disconnect the power plug of the main unit from the power out- let. 1. Unpacking A. Removal of the punch unit Disconnect the connector between the main unit and the sad- dle finisher. B. Check the packed items Check that all the items are included in the package.
  • Page 47 Remove the screw, and remove the rear cover. Remove the screw, and remove the dummy punch guide. Install the punch unit to the saddle finisher. Fix the punch unit with the screw which was removed from the Remove the screw, and remove the front lower cover. dummy punch guide.
  • Page 48 Fix the front inner cover with screws, and close the front 11) Install the saddle finisher to the main unit. cover. C. Punch jam processing label attachment Open the front cover, apply the punch jam processing label (package part No. 3) in position as shown in the figure. Fix the front lower cover with a screw.
  • Page 49 [For DSPF/RSPF] Insert the power plug of the main unit into the power outlet. DSPF Open the front cabinet. Turn ON the power switch in the front cabinet of the main unit. RSPF Turn ON the power switch on the operation panel. E.
  • Page 50: Mx-Fn11

    [9] MX-FN11 MX-M503N Service Manual Remove the skid and packing cushions. 1. Unpacking A. Removal of the finisher * For removal of the finisher, manpower of two persons or more is required. Remove the fixing material, and remove the top case. One person tilt the finisher, another person remove the lower Remove the bundled items from packing cushion.
  • Page 51 B. Removal of the protection material C. Check the packed items Remove the fixing tapes and protection material. Check that all the items are included in the package. Open the front upper door, and remove the fixing tapes and protection material. Names of bundles Quantity Binding head round tapping M4x8...
  • Page 52: Installation

    2. Installation Install the rail reception sheet metal (Package part No. 6) to the main unit with the fixing screws (Package part No. 2). <Note before installation> * Installing the MX-FN11 requires that the option desk (MX-DEX8/ DEX9) and junction unit (MX-RBX3) be installed in advance. Be sure to complete the installation of the option desk (MX-DEX8/ DEX9) and junction unit (MX-RBX3) before installing the finisher.
  • Page 53 D. Attaching the mylar Remove the reverse tray. Attach the mylar (package part No.13) to the position indicated in the figure. Reference Reference Corner reference Corner reference Remove the screws, and remove the interface left cabinet. E. Installation of the connection fixture F/R Install the connection fixture R (Package part No.
  • Page 54 F. Attaching the cushion Check that the center of the screw hole of the finisher is in the range of specification of an oval hole of the connection fixture Attach the cushion (S) (package part No.14), the cushion (M) that exist on main body rear side. (package part No.15) and the cushion (L) (package part No.16) to the position indicated in the figure.
  • Page 55 Remove the screw, slide to the left the front lower cover, and Remove the fixing tapes. remove it. Open the front upper door, and remove the screw. Remove the screws, and remove the auxiliary wheels. Remove the screws, and remove the rear lower cover. Remove the screws, and open the front cover.
  • Page 56 Loosen both of the caster fixing screws of the front side and 11) Turn the bolt for which the adjustment is necessary, and adjust rear side. to become it within the range of specification. 12) Check to insure that the upper and lower clearances between the main unit and the finisher are even.
  • Page 57 13) Tighten the caster fixing screws so that the indicator scale is 16) Install the spanner for adjustment to inside the front lower door. fit. 17) Close the front cover, and secure it with the fixing screws. 14) Install the rear lower cover with the fixing screws. 18) Attach the fixing screw, and close the front upper door.
  • Page 58 19) Attach the front lower cover with the fixing screw. Close the front cover. I. Connection of the finisher Engage the finisher to the main unit. Remove the screw, and remove the connector cover on rear side of the finisher. Install the Step screw B (Package part No.
  • Page 59 J. Connection of connector to the main unit [For DSPF/RSPF] (Package part No. 10) Connect two connectors of the finisher to the main unit, and tighten the screws. DSPF RSPF K. Staple position label attachment Attach the label to the position indicated in the figure. [For scanner] (Package part No.
  • Page 60: Mx-Pnx6A/B/C/D

    [10] MX-PNX6A/B/C/D MX-M503N Service Manual Open the front cover, and open the top cover. 1. Unpacking A. Pulling out of the punch unit Pull out the punch unit. Remove the screws, and remove the fixing material. (2 posi- tions) B. Removal of the protection material Remove the fixing tape and protection material.
  • Page 61 C. Check the packed items Hang the punch unit on the step screws installed to the fin- isher. Check that all the items are included in the package. Tighten the step screws bundled to the punch unit, fix the punch unit. Names of bundles Quantity P tight M4x12...
  • Page 62: Punch Unit

    C. Install of the Connection fixture F/R Open the front door of punch unit. Install the Connection fixture F (Package part No. 7) to the main unit with the fixing screws (Package part No. 4). Engage the pawls of the rear side of front cover (Package part Install the Connection fixture R (Package part No.
  • Page 63 E. Adjustment Open the front door of punch unit. * Refer to the adjustment procedures in the MX-FN11 Service Manual. F. Install to main unit Engage the finisher that has installed punch unit to the main unit. Check that the center of the screw hole of the punch unit is in the range of specification of an oval hole of the mounting fix- ture in front side of main unit.
  • Page 64 Close the front door of punch unit. Install the connector cover of the finisher and fix it with the fix- ing screw. Install the fixing screw (Package part No. 4 of MX-FN11) on rear side. G. Connection of connector to the main unit Connect two connectors of the finisher to the main unit, and tighten the screws.
  • Page 65 [For DSPF/RSPF] (Package part No. 12 of the MX-FN11) DSPF RSPF I. Turn ON the main power switch of the main unit Connect the power plug of the main unit into the power outlet. Open the front cabinet of the main unit. Turn ON the power switch in the front cabinet.
  • Page 66 [11] MX-TRX2 MX-M503N Service Manual Remove the power plug of the main unit from the outlet. 1. Unpacking A. Removal of the exit tray unit B. Installation of the exit roller unit Open the right door. B. Check the packed items Check that all the items are included in the package.
  • Page 67 C. Turn on the power of the main unit. Connect the connector, and install the exit roller unit (package part No. 1). Use the screw which was removed in step 3) and Insert the power plug of the main unit into the power outlet. fix the unit.
  • Page 68: Installation

    [12] MX-FXX2 MX-M503N B. Attach the fax box unit to the rear part of the Service Manual main unit. Unpacking Remove the two screws from the rear cabinet of the main unit. Attach the supplied step screw to one of the two positions from A.
  • Page 69 F. Attach the control PWB and the right cabinet Remove the two screws from the control PWB unit. rear. Pull out the control PWB unit. Push the control PWB unit into the main unit and secure it with the two screws. D.
  • Page 70 I. Clear the FAX related software switches. G. Turn on the main power switch of the main unit. Enter the SIM 66-2 mode. Insert the power plug of the main unit to the outlet. Turn on the main power switch. Enter the country code (8 digits) with the 10-key.
  • Page 71 J. Clear the image memory. L. Installation completion check Enter the SIM 66-10 mode. Execute SIM 22-10 to check to confirm that the FAX box and the FAX memory are properly installed. When the FAX1 is properly connected, "MX-FXX2" is dis- played.
  • Page 72: Ar-Su1

    [13] AR-SU1 MX-M503N Service Manual Disconnect the power plug from the power outlet. Unpacking A. Remove the stamp unit B. Install the stamp unit Open the DSPF/RSPF unit, and remove the OC mat. For removing and fixing screws, use a stubby screwdriver. B.
  • Page 73 Remove the sensor cover. Remove the stamp case, and Install the stamp cartridge (package part No. 3). remove the earth cord. Install the OC mat, and close the DSPF/RSPF unit. Attach the stamp unit (package part No. 1) to the stamp case which was removed from the DSPF/RSPF unit with the install- ing screw (package part No.
  • Page 74 C. Turn on the power of the main unit Insert the power plug into the power outlet. Open the front cabinet of the machine, and turn ON the power switch. Turn ON the power switch on the operation panel. Use SIM22-10 to check to confirm that the finish stamp (AR- SU1) is recognized.
  • Page 75: Mx-Pb10

    [14] MX-PB10 MX-M503N Service Manual 1. Unpacking A. Parts included Packed part names Quantity CD-ROM (Driver) Product key sheet (With Application Number) 2. Installation A. Preparation for enabling the MX-PB10 To enable the MX-PB10, enter the product key by the key operation of the copier machine.
  • Page 76: Unpacking

    2. Installation [15] MX-PB11 MX-M503N Service Manual A. Preliminary arrangements 1. Unpacking NOTE: When this option is installed to a machine which has been used by a user, be sure to backup the user data as shown below. When the MX-PB11 is installed, the user settings and the registered data are initialized.
  • Page 77 C. Pull out the control PWB Install the HDD to the MFP PWB frame. When installing the HDD to the MFP PWB frame, attach the • If cables are connected to the control PWB unit, remove all anti-vibration rubber to the HDD frame side and fix it with a cables.
  • Page 78 G. Preparation for enabling the MX-PB11 Push the control PWB unit into the main unit. Secure the unit with the two screws. To enable the MX-PB11, enter the product key by the key oper- ation of the copier machine. Turn on the power. (The product key input menu is dis- played.) Enter the product key with numeric key (10-key), and touch [Registration] key.
  • Page 79: Unpacking

    [16] MX-FWX1 MX-M503N B. Operation check of the Internet Fax send Service Manual function * This option requires installation of a HDD, and cannot be After completion of entry of the product key, check to confirm used with the models having no HDD. that the Internet Fax send is performed normally from the When this option is used with the U model, the MX-PB11 machine.
  • Page 80 : '10/Jun/18 MX-M503N [17] MX-EBX3 B. Type A Service Manual (1) Parts included * This option cannot be installed to the U model. 1. Unpacking A3MXEBX3* FS9205S A The MX-EBX3 is available in the following three types. Instillation must be performed according to the type. R.
  • Page 81 2. Installation Remove the screw from the right cabinet rear. Remove the right cabinet rear. A. Turn off the power of the main unit Remove the two screws from the control PWB unit. Turn the power switch located on the operation panel to the •...
  • Page 82 Remove the S tight screw (section A) of the controller PWB. Push the control PWB unit into the main unit. Use the removed S tight screw and the S tight screw provided Secure the unit with the two screws. in the package to attach the scanner function expansion PWB to the controller PWB.
  • Page 83 Open the front cabinet. Turn ON the power switch in the front cabinet of the main unit. Turn ON the power switch on the operation panel. Use SIM22-5 to check the firmware version of the MX-EBX3. The ACRE version must be 02.00.J2 or later. If the version is 01.00.J2, revise the version according to the procedure of 5).
  • Page 84: Mx-Pkx1

    [18] MX-PKX1 MX-M503N Service Manual 1. Unpacking Please keep below important information. This information will use for other products. A. Parts included APPLICATION NUMBER Packed part names Quantity CD-ROM (For Screen Font) MACHINE Product key sheet SERIAL NOTE: NUMBER • N model To set up the PS driver, do not use the CD-ROM which is included in the MX-PKX1 but use the PCL CD-ROM which is PRODUCT...
  • Page 85: Unpacking

    [19] MX-PUX1 MX-M503N Service Manual 1. Unpacking A. Check the packed items Packed part names Quantity CD-ROM Operation manual Product key sheet 2. Installation <Note before installation> To enable XPS, an expansion memory (MX-SMX3) must be installed. To install an expansion memory, refer to the descriptions of "[18] MX-SMX3"...
  • Page 86 [20] MX-SMX3 MX-M503N Service Manual Remove the two screws from the control PWB unit. • If the fax box unit is installed, carry out steps 5), 6), and 7) additionally. Unpacking Pull out the control PWB unit and remove the snap band. A.
  • Page 87 NOTE: Avoid diagonal insertion of the expansion memory Push the control PWB unit into the main unit. board for the slot. Secure the unit with the two screws. NOTE: Do not push one end of the expansion memory board by one hand. •...
  • Page 88 Turn on the main power switch. Turn on the power switch located on the operation panel. MX-M503N MX-SMX3 20 – 3...
  • Page 89: Unpacking

    [21] AR-PF1 MX-M503N B. Pull out the control PWB. Service Manual • If cables are connected to the control PWB unit, remove all cables. 1. Unpacking Push the location indicated in the illustration to unlock, and A. Parts included remove the ozone filter cover from the right cabinet rear. AR-PF1 barcode font ROM PWB Remove the screw from the right cabinet rear.
  • Page 90 D. Reattach the control PWB and the right cabinet E. Turn on the main power switch of the main rear. unit. • If the fax box unit is installed, carry out steps 1), 2), and 3) Insert the power plug of the main unit to the outlet. additionally.
  • Page 91: Installation

    : '10/Jun/18 [22] MX-FR14U/FR14/FR15U/FR15/ Service Manual Remove the power plug of the main unit from the outlet. FR24U * MX-FR14U/FR14 For model MX-M283N/M363N/M453N/M503N For model MX-M363U/M453U/M503U with HDD * MX-FR15U/FR15 For model MX-M363U/M453U/M503U without HDD * MX-FR24U For model MX-M282N/M362N/M452N/M502N Unpacking A.
  • Page 92 C. Mount the data security kit ROMs to the Fit the interface cable into the right cabinet rear cover. control PWB unit. Attach the right cabinet rear cover to the main unit. At this time, check that the four hooks are properly fitted to the Remove the ROMs (PROG1 and PROG2) from the control PWB main unit.
  • Page 93: Installation

    : '10/Jun/18 Installation MX-M503N [23] MX-KBX2 Service Manual <Note before installation> * This option cannot be installed to the following models. * Before starting installation, check to insure that the data lamp on MX-M363U/M453U/M503U the operation panel does not light up or blink. MX-M282N/M362N/M452N/M502N A.
  • Page 94 Disconnect the connector of the scan mother harness, and Attach the rear cabinet, and fix it with the screws. remove the screws. C. Install the base unit Attach the USB hub PWB unit (part No.3 in the package) with Place the protection sheet (part No.7 in the package) on the the removed screws.
  • Page 95 D. Install the operation panel Remove the screws and disconnect two connectors. Place the operation panel upside down on the protection sheet. Check that each harness is engaged with the rib. *1 *3 Connect the connector. Install the operation panel to the main unit, and fix it with the screw.
  • Page 96 F. Turn on the power of the main unit Slide and attach the operation base plate C (part No.2 in the package) to the operation base plate unit. Insert the power plug of the main unit into the power outlet. Turn ON the power switch inside the front cabinet.
  • Page 97 Touch [Keyboard Select]. S S y y s s t t e e m m S S e e t t t t i i n n g g s s D D e e f f a a u u l l t t S S e e t t t t i i n n g g s s Back Image Quality Adjustment Clock Adjust...
  • Page 98: Mx-Amx3

    [24] MX-AMX1 MX-M503N Service Manual * This option requires installation of a HDD, and cannot be used with the models having no HDD. When this option is used with the U model, the MX-PB11 and the MX-NSX1 options must be installed. 1.
  • Page 99 [25] MX-AMX2 MX-M503N Service Manual When "OSA setting" key is touched, the menu below is dis- played. * This option requires installation of a HDD, and cannot be used with the models having no HDD. When this option is used with the U model, the MX-PB11 option must be installed.
  • Page 100 [26] MX-AMX3 MX-M503N Service Manual When "OSA setting" key is touched, the menu below is dis- played. * This option requires installation of a HDD, and cannot be used with the models having no HDD. When this option is used with the U model, the MX-PB11 option must be installed.
  • Page 101: Dehumidifying Heater

    [27] Dehumidifying heater MX-M503N Service Manual Parts included Package Price Kit name Kit part code Description Part code Q'ty Remarks part No. rank Heater electric DKIT-0391FCZZ Dehumidifier heater switch QSW-C9294QCZZ component kit Label for heater switch TLABZ5256FCZZ Supporter LSUPP0118FCPZ WH PWB CPWBF1675FC338 AC-WH harness 1 DHAI-3755FCZZ...
  • Page 102 Cut the switch part of the left rear lower cabinet. Remove the snap band. Insert the supporter (package part No. 3) to the frame of the power unit, and attach the WH PWB NOTE: Be careful not to damage the cabinet. (package part No.
  • Page 103 C. Installation of the heater kit (2) Installation of the heater unit Remove the tray 1 and the tray 2. (1) Assembling of the heater unit Attach the heater (package part No. 6) to the heater mounting plate (package part No. 7), and secure it with the screw (M3x6 S-tight) (package part No.
  • Page 104 E. Installation of the scanner heater kit Attach the core (This procedure only applies to the 230V series). (1) Assembling of the scanner heater unit Attach the AC-cable connection plate (only for 120V series), or Secure the marking position on the harness of the scanner attach the inlet mounting plate (only for 230V series).
  • Page 105 (2) Removal of the table glass, the paper exit cover Connect the harness of the scanner heater. Install the heater fixing plate of the scanner heater unit, and secure it with the Remove the screw, and remove the SPF glass and the glass screw (M3x4 Round-tipped) (package part No.
  • Page 106 F. Operation check after installation Move the lamp unit by hand and check that it move smoothly in all movable area. Turn on the dehumidifier heater switch. NOTE: Check that there is no interference of the harness of the scanner heater in the wire and the 2/3 mirror unit. Measure the resistance value between the earth terminal and the AC terminal (L side), and between the earth terminal and AC terminal (N side) with the circuit tester, and confirm they...
  • Page 107: Mx-Rp11

    : '10/Jun/18 2. Installation MX-M503N [28] MX-RP11 Service Manual <Note before installation> 1. Unpacking * Before starting installation, check to insure that the data lamp on the operation panel does not light up or blink. A. Removal of the RSPF A.
  • Page 108 : '10/Jun/18 Cut the screw hole in the cabinet, and install the SPF step Raise the RSPF unit upright, and fix it with the accessory screw R (a) (package part No. 3) and the step screw R (b) screw (M5 x 16) (package part No. 4). (package part No.
  • Page 109 : '10/Jun/18 C. RSPF parallelism adjustment Make an RSPF parallelism adjustment sheet. Cut copy paper in the longitudinal direction. 20mm A4/Letter size Perform the adjustment according to the flowchart below. <Flow chart> <Work procedure> a) Check section A. Start of the Place the RSPF height adjustment sheet between section A adjustment and the RSPF glass height adjustment resin surface (a), and...
  • Page 110 : '10/Jun/18 c) Adjust the section F. Use a clearance gauge to check to confirm that the clearance in the section F is 4.3mm - 5.0mm. If not, loosen the fixing nut and turn the section E to adjust. Adjust the * Insert a clearance gauge in the range of 20mm from the section F.
  • Page 111 : '10/Jun/18 d) Check section B. Place the RSPF height adjustment sheet between section B and the RSPF glass height adjustment resin surface (a), and close the RSPF unit. Slowly pull out the RSPF height adjustment sheet. Check to insure that a slight resistance is felt when pulling out Check section B.
  • Page 112 : '10/Jun/18 D. RSPF skew adjustment (Front surface mode) [Check Method 2] Check that the squareness of the main scanning direction This adjustment is needed in the following situations: print line for the longitudinal direction of paper is within * The RSPF section has been disassembled. 1.0mm.
  • Page 113 : '10/Jun/18 Close the RSPF unit, and loosen the hex nut of the RSPF E. RSPF paper feed tray paper width sensor diagonal adjustment screw section. adjustment Turn the hex wrench of the RSPF diagonal adjustment screw This adjustment is needed in the following situations: to adjust the alignment.
  • Page 114 : '10/Jun/18 F. Copy image off-center, image lead edge Press the [EXECUTE] button, and the machine starts reading position, sub scanning direction image RSPF adjustment patterns (for the front side). magnification ratio automatic adjustment * The screen shows a message indicating that the machine is reading and calculating RSPF adjustment patterns (for the (RSPF mode) front side).
  • Page 115 LEAD-FREE SOLDER The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder. The alphabet following the LF mark shows the kind of lead-free solder. Example: <Solder composition code of lead-free solder> Solder composition Solder composition code Solder composition...
  • Page 116 CAUTION FOR BATTERY REPLACEMENT (Danish) ADVARSEL ! Lithiumbatteri – Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandoren. (English) Caution ! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
  • Page 117 Adobe, the Adobe logo, Acrobat, and the Acrobat logo are trademarks of Adobe Systems Incorporated. PCL is a registered trademark of the Hewlett-Packard Company. Sharpdesk is a trademark of Sharp Corporation. All other trademarks and copyrights are the property of their respective owners. SHARP CORPORATION...

Table of Contents