Sharp MX-M200D Service Manual page 49

Hide thumbs Also See for MX-M200D:
Table of Contents

Advertisement

Main
Sub
code
code
26
04
Copier duplex setting
Used to set YES/NO of duplex setting.
This must be set to ON when the duplex unit is installed. If this setting is set to OFF on the duplex machine,
the duplex motor dose not rotate and paper is not discharged normally, resulting in a paper jam.
Sim26-4 DUPLEX SET
1:DUPLEX
0=OFF
1=ON
[ 0-1]
05
Count mode setting
Used to set the count-up number of the total counter, the developer counter, and the maintenance counter
individually when a special paper (A3/WLT/8K) is passed.
When this simulation is executed, the current set value is displayed.
Sim26-5 COUNT MODE
1:COUNT MODE
[ 0-3]
Setting
0
1
2
3
[1]-[3] (Default:[0])
Enter a value with numeric keys, and press [OK] key or [START] key to save the current adjustment value to
the EEPROM. The machine returns to the sub code input window.
06
Destination setting
Used to set the destination of the main unit.
When this simulation is executed, the code number of currently set destination is displayed.
Sim26-6 DESTINATION
1:DESTINATION
0=JAPAN
[ 0-6]
[0] - [6] (Default: Depends on the model.)
Enter a value with numeric keys, and press [OK] key or [START] key, and the current adjustment value is
saved in the EEPROM.
[CA] key: Exits the simulation mode. (When setting is changed, the machine exits the simulation mode and
performs the hard reset.)
[INTERRUPT] key: Shifts to the sub code input window. (When setting is changed, it is invalid.)
[START] key: Setting contents are saved in the EEPROM and the machine shifts to the code input window.
(When setting is changed, the machine does not shift to the code input window.)
* When this setting is changed, the following adjustment values and the set values are automatically
changed according to the set destination.
O SIM46-19 (
O SIM46-30 (AE limit setting)
O Paper size (A4 for AB series, LT for inch series)
O Maintenance cycle (Returns to the default (Japan/Ex Japan). )
O Mini maintenance cycle (Only when setting is changed to Japan.)
Code: Duplex setting
0 : OFF
0
1 : ON
0
1
1
Total/Developer
+2
+1
+2
+1
Code
:Setting
0=JAPAN
: Japan AB series
0
1=INCH
: Inch series
2=AB
: Ex Japan AB series
3=INCH(FC)
: Ex Japan inch series (FC)
0
4=AB(FC)
: Ex Japan AB series (FC)
5=CHINESE
: China (EX Japan AB series + Chinese paper support)
6=TAIPEI
: Taiwan (EX Japan AB series + Chinese paper support)
(Setting range 0 - 6)
table setting)
MX-M200D SIMULATIONS 7-20
Contents
Maintenance
+2
+2
+1
+1
Remark
Default:
0: MX-M160
1: MX-M160D
/MX-M200D
Default:
0
Default:
Differs depending
on each destination.

Hide quick links: