Sharp MX-M200D Service Manual page 40

Hide thumbs Also See for MX-M200D:
Table of Contents

Advertisement

Main
Sub
code
code
08
06
Transfer charger output
When this simulation is executed, the machine shifts to the following mode select window, and the list of the
modes to be outputted is displayed.
Select an output mode with numeric keys and press [OK] key or [START] key, and the transfer charger
output is made for about 30sec in the specified mode.
(Mode selection window)
Sim8-6 TC OUTPUT
1:NML_A
2:NML_B
3:SML_A
EXEC
Window display
1:NML_A
2:NML_B
3:SML_A
4:SML_B
* The items of (back) is not displayed when DUPLEX setting is OFF or when MX-M160.
* Small size paper is Letter R (A4R) width or below. When an output is completed, the machine shifts to the
mode select window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window.
09
01
Duplex motor forward rotation check
Used to check the duplex motor rotation.
The duplex motor is rotated in the normal direction (paper exit direction) for 30sec.
After completion of the process, the machine shifts to the sub code input window.
(Execution start window)
Sim9-1
DMF CHECK
PRESS OK KEY EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window.
02
Duplex motor reverse rotation check
Used to check the duplex motor reverse rotation.
The duplex motor is rotated in the reverse direction for 30sec.
After completion of the process, the machine shifts to the sub code input window.
(Execution start window)
Sim9-2
DMR CHECK
PRESS OK KEY EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window.
[OK] key or [START] Key
4:SML_B
5:BYPASS
2
Output mode
Normal size width (front)
Normal size width (back)
Small size width (front)
Small size width (back)
[OK] key or [START] Key
[OK] key or [START] Key
MX-M200D SIMULATIONS 7-11
Contents
(Execution window)
Sim8-6 TC OUTPUT
1:NML_A
4:SML_B
2:NML_B
5:BYPASS
3:SML_A
EXEC
2
(Execution window)
Sim9-1
DMF CHECK
EXEC
(Execution window)
Sim9-2
DMR CHECK
EXEC
Remark
(MX-M200D/MX-
M160D only)
(Execution is not
allowed when
DUPLEX setting is
OFF.)
(MX-M200D/MX-
M160D only)
(Execution is not
allowed when
DUPLEX setting is
OFF.)