Sub
code
code
03
03
Shifter operation check
Used to reciprocate the shifter 4 times.
During execution, the status of the shifter HP sensor is displayed on the right upper section of the screen.
(When the sensor is detected, the display is highlighted.)
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
* When the above [CA] key or [INTERRUPT] key is pressed during operation of the shifter, the shifter is
returned to the home position before terminating the operations.
(Initial window)
Sim3-3 SHIFTER CHK
PRESS OK KEY EXEC
04
Job separator operation check
Used to operate the job separator up and down for 30sec.
During operation, the status of the upper limit sensor and the lower limit sensor is displayed on the right
upper section of the display.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
When the operation is interrupted, the job separator is shifted to the home position before terminating the
simulation similarly to the shifter.
(Initial window)
Sim3-4 JOBSEPA CHK
PRESS OK KEY EXEC
11
Shifter home position check
Used to check the operations of the shifter HP sensor and the shifter. When this simulation is executed, the
initial menu is displayed. By the following key operations, the left operation and the right operation of the
home position sensor and the shifter can be executed separately.
[ ] key: Shifts to R side by the specified steps.
[ ] key: Shifts to F side by the specified steps.
[ ] key: Shift to the home position.
[SFTHP] is highlighted when the HP sensor is detected.
(Initial window)
Sim3-11 SHIFTER CHK
SFTHP
[
]:R [
]:HP [
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
Contents
(Execution window)
[OK] key or [START] Key
[OK] key or [START] Key
]:F
MX-M200D SIMULATIONS 7-6
Sim3-3 SHIFTER CHK
SFTHP
EXEC
(Execution window)
Display
name
Sim3-4 JOBSEPA CHK
JSUP
JSUP
JSDL
JSDL
EXEC
Remark
Japan only
(Only when the job
separator is
installed.)
Sensor
name
Job separator
upper limit sensor
Job separator
lower limit sensor
Japan only