Sharp MX-M200D Service Manual page 42

Hide thumbs Also See for MX-M200D:
Table of Contents

Advertisement

Main
Sub
code
code
16
-
U2 trouble cancel
* Used to cancel the U2 trouble and execute the hard reset.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or
[START] key to clear the U2 trouble.
(Execution start window)
Sim16 TROUBLE CLEAR
U2 TROUBLE CLEAR
AER YOU SURE? EXEC
20
01
Maintenance counter clear
Used to clear the maintenance counter.
Press [OK] key or [START] key on the following window, the maintenance counter is cleared and the
machine returns to the sub code input window.
Sim20-1 COUNTER CLR
MAINTENANCE COUNTER
CLEAR
AER YOU SURE? EXEC
21
01
Maintenance cycle setting
Used to set the maintenance cycle. When this simulation is executed, the current set value is displayed.
Enter a desired code with numeric keys and press [START] key. The set value is saved in the EEPROM and
the machine returns to the sub code input window.
Sim21-1 CYCLE SET.
1:MAINTE CYCLE
[
0- 5]
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
22
01
Counters display
Sim22-1 COUNTER 1/4
TOTAL
:nnnnnnn
MAINTE
:nnnnnnn
DEV
:nnnnnnn(*)
MIN_MNT :nnnnnnn(*)
DRUM
:nnnnnnn
key
Sim22-1 COUNTER 2/4
CPY JOB : nnnnnnn
PRT JOB : nnnnnnn
SCN JOB : nnnnnnn
OC SCN
: nnnnnnn
key
Sim22-1 COUNTER 3/4
SPF
: nnnnnnn
DUPLEX
: nnnnnnn
OTHERS : nnnnnnn
MNTCYC : nnnnnnn
key
Sim22-1 COUNTER 4/4
DRM TTL : nnnnnnn
MMTCYC : nnnnnnn
Though SIM26-74 is set to "1: Scan counter is added," the count is not added to SIM22-01 total counter
display. The setting affects only the total counter display in the system settings.
Contents
0: 5K (5,000 sheets)
1: 7.5K (7,500 sheets)
4
2: 10K (10,000 sheets)
3: 25K (25,000 sheets)
4: 50K (50,000 sheets)
4
5: FREE (999,999 sheets)
(Setting range: 0 - 5)
key
Counter display
TOTAL
: Total counter
MAINTE : Maintenance counter
DEV
: Development counter
DRUM
: Drum counter
CPY JOB : Copy job counter
PRT JOB : Print job counter
key
SCN JOB : Scan job counter
OC SCN : OC scan counter
SPF
: SPF/RSPF counter
DUPLEX : DUPLEX counter
OTHERS : Other counter
MNTCYC : Maintenance cycle
DRM TTL :Drum rotation accumulated time
key
MX-M200D SIMULATIONS 7-13
Remark
Default:
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-m160Mx-m200dkMx-m160dMx-m160dk