Minolta Magicolor 3100 Series Service Manual page 379

Minolta laser printer service manual
Hide thumbs Also See for Magicolor 3100 Series:
Table of Contents

Advertisement

Signal line name
FAN LOW
FAN STOP
FAN REAR FAIL(H)+3.3VDC
FAN REAR ON(H)
LVPS overcurrent protection circuit
This circuit stops all outputs, if the power supply voltage 24VDC, 5VDC, or 3.3VDC is shorted.
The circuit is reset, when after the cause of short was removed, the power is turned off, and then on
again after certain time.
LVPS overvoltage protection circuit
This circuit stops all outputs, if the power supply voltage 24VDC, 5VDC, or 3.3VDC exceeds the
specified voltage respectively.
At this time, the operating point is 32VDC or less for 24VDC, 7VDC or less for 5VDC, or 6V or less
for 3.3VDC.
The circuit is reset, when the power is turned off, and then on again after certain time.
FAN output circuit
For the FAN REAR ON (H) signal, the output voltage varies depending on the status of FAN LOW
signal and FAN STOP signal.
FAN LOW
High
Low
High
Low
Output stop by Interlock Switch
Turning off the Interlock Switch mounted on the PWBA HNB DRV causes the "I/L +24VDC" circuit to
be shut off. Consequently, +24VDC supply to the PWBA HNB MCU and to the parts connected to the
PWBA HNB DRV is stopped.
Chapter 7 Wiring Diagrams and Signal Information
FAN REAR drive control signals
FAN REAR fail detection signal (High: Fail, Low: Normal)
FAN REAR ON/OFF control signal
FAN STOP
High
High
Low
Low
Description
FAN REAR ON(H)
24V
15V
0V
0V
7-379