8
Remove the MPF pick roller. See
9
Remove the MPF feeder lift plate. See
10
Remove the media vertical guide. See
11
Remove the duplex exit diverter. See
12
Remove the inner guide deflector. See
13
Remove the three screws (A) securing the media aligner roller to the machine.
14
Remove the screw (B) securing the grounding wire to the media aligner roller.
15
Locate the adjuster screw access hole in the controller board shield.
Note: The adjuster screw is contained between the left frame and the drive plate; it will stay in place during
media aligner roller replacement. If the adjuster screw needs to be replaced, then the controller board and the
main drive motor will also have to be removed to access the adjuster screw.
"MPF pick roller removal" on page
"MPF feeder lift plate removal" on page
"Media vertical guide removal" on page
"Duplex exit diverter removal" on page
"Inner guide deflector removal" on page
Repair information
318
326.
322.
321.
309.
312.
7463