PROGRAMMING
PROCEDURES
SECTION' 500-036-300
JANUARY 1988
0#2 Program-Account
Code Digit Length
Se-
lection
This program
has two sections.
The first de-
fines
the
number
of digits
required
in an ac-
count code (Forced Account
Code feature).
Enter
the number
of digits to be used (4 -
15). The
second section
sets SDTU modem
speed and re-
peat ringing.
1) Repeat
Ringing-
mark an X next to 17 if re-
peat ringing
is required.
Leave blank if stand-
ard ringing
is required.
2) Modem
Speed-mark
an X next to 15 if the
modem
speed
required
is 1200
bps. Leave
blank
if 300
bps is required.
3j Binary
Numbers-mark
an X next to 00, 01,
02,
03
and/or
04
to indicate
the
binary
number
of the account
code length.
03
Program-System
Assignments
(Options)
Seven
options
are selected
with
this pro-
gram,
using the various
keys to change
the sta-
tus of their
respective
LEDs. For the options
se-
lected,
mark an X as indicated.
1) Station
10 m
Key-mark
an X next to 10
if the m
key on station
10 is to be an m
key. Leave
blank
if m
key is required.
2) Station
10 m
Key-mark
an X next to 09
if the m
key on station
10 is to be a m
key. Leave
blank
if a
q
key is required.
3) Ringing
Modes-
mark
an X next
to 08
if
three
ringing
modes
(DAY, DAY 2, NIGHT)
are used.
Leave blank
if two ringing
modes
(DAY,
?JlGHT) are required.
4) C,O Line Groups-
mark an X next to 07 if CO
Line
Groups
feature
is allowed.
-
5) Message
Center-Station
12-mark
an X next
to 04 if station
12 is to be the Message
Cen-
ter.
6) Message
Center-Station
1 l-mark
an X next
to 03 if station
11 is to be the Message
Cen-
ter.
7) Message
Center-Station
lo-mark
an X next
to 02 if station
10 is to be the Message
Cen-
ter.
NOTES:
1. Only one station
(10,
11 or 12) may be
a Message
Center;
however,
if more than
-6-
one station
is chosen
as a Message
Cen-
ter, the lowest
numbered
station
will be
registered.
2. m keys are assigned
in
Program
4#XX.
04
Program-CO
Line Outpulsing
Selection
Selects DTMF tone (MF) or rotary-dial
pulse
(DP) outpulsing.
l
Mark an X next to the'appropriate
key/LED
if DP is required.
Leave
blank
if MF is re-
quired.
#4
Program-CO
Line Identification
Assigns
names
to the CO lines for use at
stations
with LCD-equipped
EKTs. Up to 16 char-
acters
may be used.
l
Enter the required
name(s)
in the boxes next
to the appropriate
CO line(s).
05 Program-Automatic
Recall from
Hold Tim-
ing
Sets the
timing
for the Automatic
Recall
from
Hold feature.
(Used only if LEDs 10, 11 and
12 are OFF in Program
5#XX.)
1) If recall is desired,
select a time period
of 16
-
160 seconds
and mark
an X next to the
appropriate
key/LED
in the
System
Record
Sheet. The times are not accumulative-only
one key/LED
can be selected.
2) If no recall is required,
mark an X next to 00.
0#5
Program-Camp-on
Timeout
Sets the timing
for the originating
station
to be recalled
by a CO line that was camped
on
'to a busy station
and remains
unanswered.
l
Select
a period
of time
(16 -
64 seconds)
and mark an X next to the appropriate
key/
LED on the System
Record Sheet. The times
are
not
accumulative-only
one
key/LED
can be selected.
06 Program-Automatic
Release
on Hold Ena-
ble
Selects
whether
or not the Automatic
Re-
lease on Hold (AROH) feature
is to function
on
a given
CO line. This feature
will also release
trunk-to-trunk
connections
if enabled
in Pro-
grams
02 and 0#6.
l
Mark an X next to each CO line that requires
AROH.

Advertisement

Table of Contents
loading