Brother DCP130C Service Manual page 320

Hide thumbs Also See for DCP130C:
Table of Contents

Advertisement

Selector 1:
Earth function in transfer facility
This selector determines whether or not the earth function is added to the transfer setting menu to be
accessed by the function switch.
Selectors 2 and 3: Dual tone detection frequency in ICM recording
If the machine detects either of the frequencies set by these selectors in ICM recording, it disconnects
the line. For example, if these selectors are set to "0, 0," the machine disconnects the line upon
detection of 350 or 440 Hz.
Selector 4:
Dual tone detection sensitivity in ICM recording
Setting this selector to "1" increases the tone detection sensitivity in ICM recording.
Selectors 6 through 8: Break time length for flash function
These selectors set the break time length.
This setting is effective only when the flash function is selected for the Speed Dial key by using the
function switch.
Selector
No.
1
|
1st dial tone detection
3
Max. pause time allowable for
4
remote ID code detection
5
Busy tone detection in auto-
matic sending mode
6
Busy tone detection in auto-
7
matic receiving mode
8
Not used.
NOTE: Selectors 5 through 7 are not applicable in those countries where no busy tone detection is
supported.
WSW05
(1st dial tone and busy tone detection) (Not used.)
Function
Setting and Specifications
No. 1 2 3
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
0 : 2 seconds
No. 5 6
0 0 :
0 1 :
1 0 :
1 1 :
0 : Yes
App. 4-7
:
3.5 sec. WAIT
:
7.0 sec. WAIT
:
10.5 sec. WAIT
:
14.0 sec. WAIT
:
17.5 sec. WAIT
:
21.0 sec. WAIT
:
2.5 sec. WAIT
:
Detection (Without WAIT)
1: 1 second
No detection
Detection only after dialing
No detection
Detection before and after dialing
1: No
sec.: second(s)