Sign In
Upload
Manuals
Brands
Addi-Data Manuals
Network Hardware
MSX-E1701
Addi-Data MSX-E1701 Manuals
Manuals and User Guides for Addi-Data MSX-E1701. We have
4
Addi-Data MSX-E1701 manuals available for free PDF download: Manual, Technical Description, Quick Installation
Addi-Data MSX-E1701 Manual (51 pages)
Brand:
Addi-Data
| Category:
I/O Systems
| Size: 2 MB
Table of Contents
Table of Contents
4
1 Definition of Application
7
Intended Use
7
Usage Restrictions
7
General Description of the Board
7
Characteristics
7
Safety Precautions
7
Current Sources
7
Degrees of Protection
7
Cables
8
Housing
8
Connection
8
Remarks
8
2 User
9
Qualification
9
Personal Protection
9
3 Handling of the Ethernet I/O Module
10
Fig. 3-1: Correct Handling
10
4 Technical Data
11
Electromagnetic Compatibility (EMC)
11
Physical Set-Up
11
Dimensions
11
Fig. 4-1: Dimensions
11
Limit Values
12
Ethernet
12
Fig. 4-2: MSX-E1701: View from above
12
Trigger Input
13
Synchro Inputs and Outputs
13
Digital Inputs
13
Digital Outputs
14
5 Use
15
Before Use
15
Mounting the Ethernet I/O Module: DIN Rail
15
Fig. 5-1: Use
15
Mounting the Ethernet I/O Module: Angle Mounting
16
Fig. 5-2: Clamps
16
Fig. 5-3: Angles Pointing to the Outside
16
Fig. 5-4: Angles Pointing to the Inside
16
Fig. 5-5: Screws and Seals
17
Fig. 5-6: Angle Mounting
17
Connecting the Components
18
Connecting the Digital Functions
18
Fig. 5-7: Selecting a Digital Plug
18
Connecting Ethernet Ports
19
Connecting Trigger and Synchro Signals
19
Fig. 5-8: Connecting Ethernet Ports
19
Fig. 5-9: Connecting Trigger and Synchro Signals
19
Connecting to the Current Supply
20
Connecting Several Ethernet I/O Modules
20
Fig. 5-10: Connecting the Current Supply
20
Fig. 5-11: Connecting Several Ethernet I/O Modules
21
LED Display
22
Fig. 5-12: Leds: Current Supply, Ethernet and Status
22
Fig. 5-13: Leds: Digital I/O
22
LED "Status
23
Table 5-1: LED "Status
23
6 Connecting the Peripheral
25
Pin Assignment Control Signals
25
Ethernet Ports
25
Fig. 6-1: Control Signals MSX-E1701
25
Table 6-1: Pin Assignment: Ethernet Port 0 and Port 1
25
Trigger/Sync
26
Current Supply
26
Table 6-2: Pin Assignment: Trigger/Synchro
26
Table 6-3: Pin Assignment: Current Supply
26
Signals of the Counter and Digital Functions
27
Table 6-4: Pin Assignment of the Digital I/O
27
7 Software
28
Option 1: Direct Access
28
Interface to the Module
28
SOAP: General Definition
28
Fig. 7-1: SOAP in the TCP/IP Protocol Staple
28
SOAP Functions
29
Data Server and Data Protocol
29
Option 2: Access with ADDIPACK
30
Module Registration
30
A) Assigning the IP Address
30
B) Module Registration
30
Inserting the Module
30
Fig. 7-2: Board Type List
31
Fig. 7-3: Settings
31
Fig. 7-4: Settings OK
32
Fig. 7-5: Settings Not OK
32
Fig. 7-6: ADDIREG Main Window (Example)
33
Fig. 7-7: Addevice Manager
33
Description of the ADDIREG Program
34
Questions and Software Downloads on the Web
35
Fig. 7-8: Board Clear/Insert
35
Standard Software
37
A) Software Functions
37
Table 7-1: Supported Software Functions
37
B) Software Samples
39
Table 7-2: Supported Software Samples for the Ethernet I/O Module
39
Webserver
40
Table 7-3: Webserver: Further Points
40
Software Tool Setmsxexxxx
41
Fig. 7-9: SET MSX-Exxx: Main Menu
41
Fig. 7-10: New IP Address Changed
44
8 Functions of the Module
45
Block Diagram
45
Connection Examples: Digital I/O
45
Connection Example: Digital Inputs (24 V)
45
Fig. 8-1: Block Diagram
45
Fig. 8-2: Connection Example: Digital Inputs (24 V)
45
Connection Example: Digital Outputs (24 V)
46
Function Description: Digital Outputs and Diagnostics
46
Fig. 8-3: Connection Example: Digital Outputs (24 V)
46
Watchdog
47
9 Appendix
48
Glossary
48
Index
50
Advertisement
Addi-Data MSX-E1701 Manual (47 pages)
Intelligent Ethernet counter/digital I/O module
Brand:
Addi-Data
| Category:
Control Unit
| Size: 2 MB
Table of Contents
Table of Contents
4
Definition of Application
8
Intended Use
8
Usage Restrictions
8
General Description of the Board
8
Characteristics
8
Safety Precautions
8
Current Sources
8
Degrees of Protection
8
Cables
8
Housing
9
Connection
9
Remarks
9
User
10
Qualification
10
Personal Protection
10
Handling of the Ethernet I/O Module
11
Fig. 3-1: Correct Handling
11
Technical Data
12
Electromagnetic Compatibility (EMC)
12
Physical Set-Up
12
Dimensions
12
Fig. 4-1: Dimensions
12
Limit Values
13
Ethernet
13
Fig. 4-2: MSX-E1701: View from above
13
Trigger Input
14
Synchro Inputs and Outputs
14
Counter
14
Use
15
Before Use
15
Mounting the Ethernet I/O Module: DIN Rail
15
Fig. 5-1: Use
15
Mounting the Ethernet I/O Module: Angle Mounting
16
Fig. 5-2: Clamps
16
Fig. 5-3: Angles Pointing to the Outside
16
Fig. 5-4: Angles Pointing to the Inside
16
Fig. 5-5: Screws and Seals
17
Fig. 5-6: Angle Mounting
17
Connecting the Components
18
Connecting the Counter Function
18
Fig. 5-7: Selecting a Counter Plug
18
Connecting Ethernet Ports
19
Connecting Trigger and Synchro Signals
19
Fig. 5-8: Connecting Ethernet Ports
19
Fig. 5-9: Connecting Trigger and Synchro Signals
19
Connecting to the Current Supply
20
Connecting Several Ethernet I/O Modules
20
Fig. 5-10: Connecting the Current Supply
20
Fig. 5-11: Connecting Several Ethernet I/O Modules
21
LED Display
22
Overview
22
Fig. 5-12: Leds: Current Supply, Ethernet and Status
22
Fig. 5-13: Leds: Counter
22
LED "Status
23
Table 5-1: LED "Status
23
Connecting the Peripheral
25
Pin Assignment Control Signals
25
Ethernet Ports
25
Fig. 6-1: Control Signals MSX-E1701
25
Table 6-1: Pin Assignment: Ethernet Port 0 and Port 1
25
Trigger/Synchro
26
Current Supply
26
Table 6-2: Pin Assignment: Trigger/Synchro
26
Table 6-3: Pin Assignment: Current Supply
26
Signals of the Counter Functions
27
Table 6-4: Overview: Pin Assignment Counter
27
Jumper: Selection of the Supply Voltage
28
Fig. 6-2: Pin Assignment: Counter
28
Fig. 6-3: Counter: 24 V Supply: Jumper on 1 and 2
28
Fig. 6-4: Counter: 5 V Supply: Jumper on 2 and 3
28
TTL-Signal at RS485-Input
29
Connection Example: Incremental Encoder
29
Fig. 6-5: Connection Example: Incremental Encoder
29
Software
31
Direct Access
31
Interface to the Module
31
SOAP: General Definition
31
Fig. 7-1: SOAP in the TCP/IP Protocol Staple
31
SOAP Functions
32
Data Server and Data Protocol
32
Questions and Software Downloads on the Web
33
Webserver
34
Fig. 7-2: Webserver: Module Information
34
Table 7-1: Webserver: Further Points
34
Software Tool Setmsxexxxx
35
Fig. 7-3: SET MSX-Exxx: Main Menu
35
Fig. 7-4: New IP Address Changed
38
Functions of the Module
39
Block Diagram: MSX-E1701
39
Block Diagram: Incremental Counter
39
Fig. 8-1: Block Diagram: MXS-E1701
39
Fig. 8-2: Block Diagram: Incremental Counter
39
Function Description: Incremental Counter
40
Single/Double/Quadruple/Direct Mode
40
Single Mode
40
Double Mode
40
Table 8-1: Acquisition Modes
40
Quadruple Mode
41
Direct Mode
41
Hysteresis Function
41
Fig. 8-3: Example: Quadruple Mode, Hysteresis on
41
Fig. 8-4: Example: Quadruple Mode, Hysteresis off
41
Frequency Measurement
42
Compare Logic
42
Absolute Mode
42
Modulo Mode
43
Index and Reference Point Logic
43
Fig. 8-5: Compare Logic
43
Digital Trigger
44
Synchro Function
44
Programmable Filters for Counter Inputs
44
Appendix
45
Addi-Data MSX-E1701 Technical Description (40 pages)
Ethernet multifunction counter system
Brand:
Addi-Data
| Category:
Network Hardware
| Size: 0 MB
Table of Contents
Warning
3
Table of Contents
4
Chapter Overview
6
1 Definition of Application, User, Handling
7
Definition of Application
7
Intended Use
7
Usage Restrictions
7
Limits of Use
7
Safety Precautions
7
Current Sources
7
Degrees of Protection
7
Cables
8
Housing
8
User
8
Qualification
8
Country-Specific Regulations
8
Handling of the Ethernet System
9
Questions and Updates
9
Fig. 1-1: Correct Handling
9
2 Brief Description
10
Functions and Features
10
Block Diagram
11
Fig. 2-1: MSX-E1701: Block Diagram
11
3 Function Description: Incremental Counter Inputs
12
Pin Assignment
12
Table 3-1: Pin Assignment: Incremental Counter Inputs
12
Table 3-2: Pin Assignment: Incremental Counter Inputs (MSX-E1701-24V)
13
Selecting the Supply Voltage
14
Fig. 3-1: MSX-E1701: Right-Hand Side of the Housing
14
Fig. 3-2: 24 V Supply: Jumper at Positions 1 and 2
14
Connection Example
15
Fig. 3-3: 5 V Supply: Jumper at Positions 2 and 3
15
Fig. 3-4: Connection Example: Incremental Encoder
15
TTL Signal to RS422 Input
16
Acquisition Modes
16
Table 3-3: Incremental Counter: Acquisition Modes
16
Fig. 3-5: Incremental Counter: Single Mode
17
Fig. 3-6: Incremental Counter: Double Mode
17
Fig. 3-7: Incremental Counter: Quadruple Mode
17
Fig. 3-8: Incremental Counter: Direct Mode
17
Options
18
Frequency Measurement
18
Compare Logic
18
Fig. 3-9: Quadruple Mode: Hysteresis "On
18
Fig. 3-10: Quadruple Mode: Hysteresis "Off
18
Index and Reference Point Logic
19
Hardware Trigger
19
Digital Filter for the Incremental Counter Inputs
20
4 Function Description: Digital Inputs/Outputs
21
Pin Assignment
21
Table 4-1: Pin Assignment: Digital Inputs/Outputs
21
LED Display
22
Table 4-2: LED Display: Digital I/O
22
Connection Examples
23
Digital Inputs (24 V)
23
Fig. 4-1: Connection Example: Digital Inputs (24 V)
23
Digital Outputs (24 V)
24
Digital Outputs
24
Fig. 4-2: Connection Example: Digital Outputs (24 V)
24
Watchdog
25
5 Function Description: PWM Outputs
26
Pin Assignment
26
Table 5-1: Pin Assignment: PWM Outputs
26
6 Web Interface: Quick Access to the MSX-E System
27
I/O Configuration
27
Menu Item "Digital I/O
27
Menu Item "I/O Watchdog
27
Fig. 6-1: Digital I/O: Channels
27
Fig. 6-2: Digital I/O: Rearm
27
Fig. 6-3: I/O Watchdog: Current State
27
Menu Item "Incremental Counter
28
Fig. 6-4: I/O Watchdog: Configuration
28
Fig. 6-5: Incremental Counter: Configuration
28
Menu Item "PWM
29
Fig. 6-6: PWM: Configuration
29
Data Format
30
Table 6-1: Incremental Counter: Data Format
30
Table 6-2: Data
30
7 Technical Data and Limit Values
31
Electromagnetic Compatibility (EMC)
31
Mechanical Structure
31
Fig. 7-1: MSX-E1701: Dimensions
31
Fig. 7-2: MSX-E1701: View from above
31
Versions
32
Limit Values
32
Table 7-1: MSX-E1701: Versions
32
Ethernet
33
Trigger Input
33
Synchro Input and Output
33
Incremental Counter Inputs
34
Pwm
34
Digital Inputs
34
Digital Outputs
35
Watchdog
35
8 Appendix
36
Glossary
36
Index
39
9 Contact and Support
40
Advertisement
Addi-Data MSX-E1701 Quick Installation (8 pages)
Ethernet multifunction counter system
Brand:
Addi-Data
| Category:
Measuring Instruments
| Size: 0 MB
Advertisement
Related Products
Addi-Data MSX-E1516
Addi-Data MSX-E Series
Addi-Data MSX-E3701-DIO
Addi-Data MSX-Box-500
Addi-Data MSX-ilog Series
Addi-Data MSX-AI-5000
Addi-Data Categories
I/O Systems
PCI Card
Measuring Instruments
Data Loggers
Computer Hardware
More Addi-Data Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL