Web interface: Quick access to the MSX-E system
6.1.5 Data format
Below, the data format of incremental counter values is described. The data server is not used for the
digital I/Os and the watchdog.
Time stamp (μs)
4 Bytes
Time stamp in
microseconds
A data packet consists of five fields (field format: 32-bit Little Endian). The data width of all data is
32-bit.
0: Compare logic
1: Frequency measurement
2: Latch value via the digital hardware
trigger
3: Latch value via the synchro trigger
4: Latch value via the index input
www.addi-data.com
Table 6-1: Incremental counter: Data format
Time stamp (s)
4 Bytes
Time stamp in
Number of the
seconds
incremental
counter (0 to 3)
Table 6-2: Data
Event source
Counter No.
Event source
4 Bytes
see Table 6-2
Result
Counter value
Number of pulses within
the defined interval
Counter value
Counter value
Counter value
30
MSX-E1701
Data
4 Bytes
4 Bytes
see Table 6-2
Need help?