Calibration Settings
For a better scan quality, the ArtixScan 3200XL can be set and calibrated with
ScanWizard Pro based on your preferences.
To activate the Calibration Settings, go to the Menu bar at
the top of ScanWizard Pro and then click the Preferences
menu. Click on the "Calibration Settings" command to
activate the sub-menu.
Smart Calibration Mode
This is the default setting of the program.
When this option is selected, ScanWizard
Pro will memorize the calibration values
generated by different scanning settings the
first time when you launch the ScanWizard
Pro.
When you perform the next scan job, the
scanner will skip the calibration step and
directly execute your order. This mode
enhances the scanning speed enormously.
Reset All Calibration Data
If you click on the Execute button in the Smart Calibration Mode, ScanWizard Pro will
delete all saved calibration data; therefore, the program will need to recalibrate your
scanner to memorize the calibration values before you perform a scan job. This option
is useful to check the precision and quality of the scanner.
Typical Calibration Mode
If this option is selected, ScanWizard Pro will
calibrate the scanner every time before
performing a scan job. This mode takes more
time, but ensures an optimal scan quality
each time you scan.
Please take note that when the Calibration
Mode is set as Typical, the scanner will
proceed directly once the calibration is
finished. Therefore, you need to put the
document to scan on the scan bed in advance.
ArtixScan 3200XL User Guide
21