Trigger - Photon Focus CameraLink MV1-D1280 User Manual

Cmos area scan camera / cameralink series
Table of Contents

Advertisement

8.1.3 Trigger

This tab contains trigger and strobe settings.
Figure 8.4: Trigger panel
Trigger
Trigger Source:
Free running: The camera continuously delivers images with a certain configurable frame rate.
Interface Trigger: The Trigger signal is applied to the camera by the CameraLink frame grabber
or the USB interface respectively.
I/O Trigger: The trigger signal is applied directly to the camera on the power supply connector.
Further trigger settings:
Trigger Delay [ms]: Programmable delay in milliseconds between the incoming trigger edge
and the start of the exposure.
Trigger signal active low: Define the trigger signal to be active high (default) or active low.
Burst Trigger
An external trigger event start a predefined number of acquisition. The period time between
the acquisitions can be configured.
8.1 MV1-D1280-120
61

Advertisement

Table of Contents
loading

Table of Contents