Sign In
Upload
Manuals
Brands
Photon Focus Manuals
Digital Camera
MV0 CMOSIS Series
Photon Focus MV0 CMOSIS Series Manuals
Manuals and User Guides for Photon Focus MV0 CMOSIS Series. We have
2
Photon Focus MV0 CMOSIS Series manuals available for free PDF download: User Manual
Photon Focus MV0 CMOSIS Series User Manual (123 pages)
Pregius CMOS camera series with GigE Interface
Brand:
Photon Focus
| Category:
Digital Camera
| Size: 7 MB
Table of Contents
Table of Contents
3
1 Preface
7
Important Notice
7
About Photonfocus
8
Contact
8
Sales Offices
8
Further Information
8
Legend
9
2 Introduction
11
Camera Naming Convention
11
Camera List
12
3 Product Specification 3.1 Introduction
13
Feature Overview
15
Technical Specification
16
Absolute Maximum Ratings
17
Electrical Characteristics
18
Spectral Response
18
RGB Bayer Pattern Filter (Color Models)
22
Polarized Pattern Filter (Polarized Models)
23
4 Image Acquisition
25
Overview
25
Vocabulary
25
Structure
25
Image Acquisition, Frame and Exposure Control Parameters
26
Image Acquisition, Frame and Exposure Trigger
27
Image Acquisition, Frame and Exposure Status
27
Acquisition Control
28
Acquisition Start and Stop Commands, Acquisition Mode and Acquisition Frame Count
28
Acquisition Frame Rate and Acquisition Frame Rate Enable
28
Acquisition Start Trigger
29
Acquisition End Trigger
30
Acquisition Control Output Signals
30
Frame Control
31
Frame Start Trigger
31
Frame Burst Start Trigger
31
Frame Burst End Trigger
32
Frame Control Output Signals
33
Exposure Control
34
Exposure Mode
34
Exposure Start Trigger
34
Exposure End Trigger
34
Exposure Control Output Signals
35
Overlapped Image Acquisition Timing
36
Acquisition-, Frame- and Exposure-Trigger Configuration
38
Trigger Source Selection
38
Trigger Software
39
Trigger Mode
39
Trigger Activation
39
Trigger Divider
40
Trigger Delay
40
Software Signal Pulse and User Output
41
5 Counter & Timer
43
Counter
43
Counter Usage
43
Counter Status
44
Counter Active, -Start and -End Signal
44
Counter Reset
44
Counter Event Source
45
Counter Trigger Source
46
Counter Reset Source
47
Timer
48
Timer Usage
49
Timer Status
49
Timer Active, -Start and -End Signal
49
Timer Reset
50
Timer Trigger Source
50
6 O Control
51
Input Signal Path
51
Output Signal Path
51
7 Action Control
53
Action Command Usage
53
Action Control Output
54
8 User Storage
55
9 Image Format Control
57
Region of Interest (ROI)
57
Multiple Regions of Interest (MROI)
57
Pixel Format
59
10 Frame Rate
61
Exposure Time Is Dominant
61
Image Size Is Dominant
61
Maximum Frame Rate
62
11 Image Data Processing
65
Overview
65
Gain and Offset
66
Grey Level Transformation (LUT)
66
Gain
67
User-Defined Look-Up Table
68
Region LUT and LUT Enable
68
Binning
71
Description
71
Camera Settings
71
Dual Crosshairs
72
Test Images
74
Ramp
74
Lfsr
74
Troubleshooting Using the LFSR
74
Status Line and Image Information
76
Image Average Value
76
Status Line Format
76
Camera Type Codes
78
Frame Combine
79
Frame Combine Timeout
79
Double Rate (DR Cameras Only)
81
12 Precautions
83
Important Notice
83
13 Hardware Interface
87
Absolute Maximum Ratings
87
Electrical Characteristics
87
Gige Camera Connector
87
Power over Ethernet (Poe)
87
Status Indicator (Gige Cameras)
88
I/O Connector
89
Overview
89
Encoder Interface
90
Single-Ended Line Input
90
Single-Ended Line Output
92
Master / Slave Camera Connection
93
14 Mechanical Considerations
95
Mechanical Interface
95
MV0 Cameras with Gige Interface
95
OEM0 Cameras with Gige Interface
96
OEM0 Camera Heat Sink Design
98
Optical Interface
99
Cleaning the Sensor
99
15 Troubleshooting
101
No Images Can be Acquired
101
No Acquisition Due to no Triggers
101
16 Standards Compliance
103
Directives and General Standards
103
Country-Specific Information
103
For Customers in the USA
103
For Customers in Canada
104
Pour Utilisateurs au Canada
104
Life Support Applications
104
17 Warranty
105
Warranty Terms
105
Warranty Claim
105
Breach of Warranty
105
18 Support and Repair
107
Technical Support
107
Repair and Obtaining an RMA Number
107
Temporal Abandoning and Scrapping
107
19 References
109
A Pinouts
111
I/O Connector
111
Gige Connector
111
B Camera Timing
113
Timed Exposure Mode Camera Timing
113
C Use Cases
115
Acquisition
115
Camera Runs in "Free-Running" Mode
115
Camera Runs in "Constant Frame Rate" Mode
115
Camera Runs in Triggered Mode
116
Camera Runs in Burst Triggered Mode
116
Triggered Controlled Exposure Mode
117
Timer
118
Strobe Signal Output
118
Counter
119
Counter Reset
119
Image Counter
119
Real Time Counter
119
Missed Trigger Counter
120
Look-Up Table (LUT)
121
Overview
121
Full ROI LUT
121
Region LUT
121
User Defined LUT Settings
121
Predefined LUT Settings
122
D Document Revision History
123
Advertisement
Photon Focus MV0 CMOSIS Series User Manual (111 pages)
CMOS camera series with GigE Interface
Brand:
Photon Focus
| Category:
Digital Camera
| Size: 6 MB
Table of Contents
Table of Contents
3
1 Preface
7
Important Notice
7
About Photonfocus
8
Contact
8
Sales Offices
8
Further Information
8
Legend
9
2 Introduction
11
Camera Naming Convention
11
Camera List
11
3 Product Specification 3.1 Introduction
13
Feature Overview
15
Technical Specification
15
Absolute Maximum Ratings
17
Electrical Characteristics
17
Spectral Response
18
RGB Bayer Pattern Filter (Color Models)
20
4 Image Acquisition
21
Overview
21
Vocabulary
21
Structure
21
Image Acquisition, Frame and Exposure Control Parameters
22
Image Acquisition, Frame and Exposure Trigger
23
Image Acquisition, Frame and Exposure Status
23
Acquisition Control
24
Acquisition Start and Stop Commands, Acquisition Mode and Acquisition Frame Count
24
Acquisition Frame Rate and Acquisition Frame Rate Enable
24
Acquisition Start Trigger
25
Acquisition End Trigger
26
Acquisition Control Output Signals
26
Frame Control
27
Frame Start Trigger
27
Frame Burst Start Trigger
27
Frame Burst End Trigger
28
Frame Control Output Signals
29
Exposure Control
30
Exposure Mode
30
Exposure Start Trigger
30
Exposure End Trigger
30
Exposure Control Output Signals
31
Overlapped Image Acquisition Timing
32
Acquisition-, Frame- and Exposure-Trigger Configuration
34
Trigger Source Selection
34
Trigger Software
35
Trigger Mode
35
Trigger Activation
35
Trigger Divider
36
Trigger Delay
36
Software Signal Pulse and User Output
37
5 Counter & Timer
39
Counter
39
Counter Usage
39
Counter Status
40
Counter Active, -Start and -End Signal
40
Counter Reset
40
Counter Event Source
41
Counter Trigger Source
42
Counter Reset Source
43
Timer
44
Timer Usage
45
Timer Status
45
Timer Active, -Start and -End Signal
45
Timer Reset
46
Timer Trigger Source
46
6 O Control
47
Input Signal Path
47
Output Signal Path
47
7 Action Control
49
Action Command Usage
49
Action Control Output
50
8 Image Format Control
51
Region of Interest (ROI)
51
9 Frame Rate
53
Exposure Time Is Dominant
53
Image Size Is Dominant
53
Maximum Frame Rate
53
10 High Dynamic Range Mode (HDR)
55
Multiple Slope Mode (High Dynamic Range)
55
11 Image Data Processing
57
Overview
57
Column FPN Correction
59
Enable / Disable the Column FPN Correction
59
Calibration of the Column FPN Correction
59
Storing the Calibration in Permanent Memory
60
Gain and Offset
60
Grey Level Transformation (LUT)
61
Gain
61
Gamma
63
User-Defined Look-Up Table
64
Region LUT and LUT Enable
64
Crosshairs
67
Status Line and Image Information
69
Image Average Value
69
Status Line Format
69
Camera Type Codes
71
Test Images
72
Ramp
72
Lfsr
72
Troubleshooting Using the LFSR
72
12 Precautions
75
Important Notice
75
13 Hardware Interface
79
Absolute Maximum Ratings
79
Electrical Characteristics
79
Gige Camera Connector
79
Power over Ethernet (Poe)
79
Status Indicator (Gige Cameras)
80
I/O Connector
81
Overview
81
Single-Ended Line Input
82
Single-Ended Line Output
83
Master / Slave Camera Connection
84
14 Mechanical Considerations
85
Mechanical Interface
85
Cameras with Gige Interface
85
Optical Interface
86
Cleaning the Sensor
86
15 Troubleshooting
89
No Images Can be Acquired
89
No Acquisition Due to no Triggers
89
16 Standards Compliance
91
Directives and General Standards
91
Country-SpecifiC Information
91
For Customers in the USA
91
For Customers in Canada
92
Pour Utilisateurs Au Canada
92
Life Support Applications
92
17 Warranty
93
Warranty Terms
93
Warranty Claim
93
Breach of Warranty
93
18 Support and Repair
95
Technical Support
95
Repair and Obtaining an RMA Number
95
Temporal Abandoning and Scrapping
95
19 References
97
A Pinouts
99
I/O Connector
99
Gige Connector
99
B Camera Timing
101
Timed Exposure Mode Camera Timing
101
C Use Cases
103
Acquisition
103
Camera Runs in "Free-Running" Mode
103
Camera Runs in "Constant Frame Rate" Mode
103
Camera Runs in Triggered Mode
104
Camera Runs in Burst Triggered Mode
104
Triggered Controlled Exposure Mode
105
Timer
106
Strobe Signal Output
106
Counter
107
Counter Reset
107
Image Counter
107
Real Time Counter
107
Missed Trigger Counter
108
Look-Up Table (LUT)
109
Overview
109
Full ROI LUT
109
Region LUT
109
User Defined LUT Settings
109
Predefined LUT Settings
110
D Document Revision History
111
Advertisement
Related Products
Photon Focus MV0-D2048x1088-C01-160-G2
Photon Focus MV0-D2048-C01-160-G2
Photon Focus MV0 3D06 Series
Photon Focus MV0-D2048x1088-C01-3D06-768-G2
Photon Focus MV0-D2048-C01-3D06-768-G2
Photon Focus Python MV0-D1280-O01-3D06-288-G2
Photon Focus Python MV0-D1984-O01-3D06-576-G2
Photon Focus Python MV0-D2592-O01-3D06-576-G2
Photon Focus MV0-D1920-S01-240-G2
Photon Focus MV0-D2448-S01-240-G2
Photon Focus Categories
Digital Camera
Security Camera
Color Camera
Scanner
Accessories
More Photon Focus Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL