5.2.6 Trigger timing values

Table 5.7 shows the values of the trigger timing parameters.
Timing Parameter
t
d iso input
t
jitter
t
trigger delay
t
burst trigger delay
t
burst period time
t
trigger offset
t
trigger offset
t
exposure
t
strobe delay
t
strobe offset
t
strobe offset
t
strobe duration
t
d iso output
t
trigger pulsewidth
Number of bursts n
Table 5.7: Summary of timing parameters relevant in the external trigger mode using the D-120 cameras
.
34
(non burst mode)
(burst mode)
(non burst mode)
(burst mode)
D-120
Minimum
45 ns
0
0
0
depends on camera settings
1.43 µs
1.45 µs
13.3 µs
0
66.6 ns
83.3 ns
200 ns
45 ns
200 ns
1
D-120
Maximum
60 ns
16.6 ns
0.279 s
0.279 s
0.279 s
1.43 µs
1.45 µs
0.279 s
0.279 s
66.6 ns
83.3 ns
0.279 s
60 ns
n/a
30000