8 Graphical User Interface (GUI)

8.1.1 Exposure

This tab contains exposure settings.
Figure 8.2: Exposure panel
Exposure
Exposure time [ms]: Configure the exposure time in milliseconds.
Constant Frame Rate: When the Constant Frame Rate (CFR) is switched on, the frame rate
(number of frames per second) can be varied from almost 0 up to the maximum frame
rate. Thus, fewer images can be acquired than would otherwise be possible. When
Constant Frame Rate is switched off, the camera delivers images as fast as possible,
depending on the exposure time and the read-out time.
Frame time [ms]: Configure the frame time in milliseconds. Only available if Constant Frame
Rate is enabled. The minimum frame time depends on the exposure time and readout
time.
Black Level Offset
It may be necessary to adjust the black level offset of the camera.
Black Level Offset: Black level offset value. Use this to adjust the black level.