Problems With No Fault Display - WMF WMF1000 User Manual

Coffee machine
Table of Contents

Advertisement

Messages and tips

8.3 Problems with no fault display

Error
No milk foam/milk
output, but milk in
reservoir
No milk foam,
only hot milk
Milk or milk foam
is too cold
Milk is too hot and there
is too little or
milk foam has bubbles
All-in-one spout:
Assembly/disassembly
is stiff
Water tank stiff
Display side doors open
Pump makes loud
noises
52
Action
Check that milk hose is not kinked or crimped, lay milk
hose again
Clean all-in-one spout and milk nozzle
See Chapter 6 Customer Care > Milk system cleaning.
Put milk lever in milk foam position
Carry out foamer rinse, pushing spout completely
upwards
If necessary, check whether the air intake nozzle of the
all-in-one spout is stopped up
Ensure that the milk nozzle is on the milk hose
Check whether the correct milk nozzle is mounted
(transparent for refrigerated milk)
Milk is too warm:
Refrigerate milk
Check that milk hose is not kinked or crimped
Lay milk hose again
Check whether the correct milk nozzle is mounted
(grey for unrefrigerated milk)
Leakage:
Check all connections and seals of the all-in-one spout
Milk lever is not all the way up for milk foam or not all
the way down for milk
Lightly smear o-rings with WMF sealing grease and
make sure that no grease gets into the air intake
opening
The grease for sealing rings is in the accessories box.
Lightly smear O-rings with WMF sealing grease
Brewing unit is not inserted correctly or doors are not
closed correctly - check! The lever labeled "Press" must
always be in the level position.
Water tank is not inserted correctly (air in the system).
Push water tank in completely
Bleed machine:
Dispense hot water until a constant stream of water
comes out
Hint: it is normal if during operation the water pump
runs independently from time to time; it fills the system
automatically.
WMF 1000 user manual