If The Automatic White Balance Adjustment Cannot Be Made - Sony HDW-790P Operation Manual

Hide thumbs Also See for HDW-790P:
Table of Contents

Advertisement

If the setting of the FILTER selector is changed, a
message reporting the setting appears for about 3
seconds in the setting change and adjustment progress
message display area of the viewfinder screen (in
display mode 3).
3
Place a white test card under the same lighting
conditions as those for the subject to be shot and zoom
in to it.
Alternatively, any white object such as a cloth or a wall
can be used.
The absolute minimum white area is as follows:
Note
Make sure there are no bright spots in the rectangle.
4
Adjust the lens iris.
Manually adjusted lens: Set the iris to an appropriate
setting.
Lens with automatic iris: Set the automatic/manual
switch on the lens to automatic.
5
Push the AUTO W/B BAL switch to WHT and then
release the switch.
AUTO W/B BAL switch
The switch returns to the center position, and the
adjustment is executed.
During adjustment, the message "AWB :
EXECUTING" is displayed on the viewfinder screen
(in display mode 2 or 3).
The white balance adjustment ends in about 1 second
with the message shown in the following figure. The
60
Adjusting the Black Balance and the White Balance
Rectangle centered on
the screen. The lengths of
the sides are 70% of the
length and width of the
screen.
The white object must be
within the rectangle and
have an area of at least
10% of the screen.
adjustment setting is automatically stored in the
memory (A or B) that was selected in step 1 using the
WHITE BAL switch.
Note
If the camera has a zoom lens with an automatic iris, the
1)
iris may hunt
during the adjustment. To prevent this,
adjust the iris gain knob (indicated as IG, IS, or S) on the
lens.
1) Hunting
Repeated brightening and darkening of the image, resulting from repeated
response to automatic iris control.
For details, refer to the lens operating manual of the lens.
If the automatic white balance adjustment
cannot be made
If the white balance adjustment cannot be completed
normally, an error message will appear for about 3 seconds
on the viewfinder screen (in display mode 2 or 3).
Possible messages are listed below.
White balance adjustment error messages
Error message
Meaning
AWB : NG
The white video level is too low.
LOW LEVEL
Either open the lens iris or increase
the gain.
AWB : NG
The color temperature is too high.
COLOR TEMP HIGH
Select a suitable filter setting.
AWB : NG
The color temperature is too low.
COLOR TEMP LOW
Select a suitable filter setting.
AWB : NG
Adjustment could not be completed
TIME LIMIT
within the standard number of
attempts.
AWB : NG
The white area could not be
POOR WHITE AREA
checked.
AWB : NG
The white video level is too high.
OVER LEVEL
Either step down the lens iris or
change the ND filter.
If any of the above error messages is displayed, retry the
white balance adjustment. If the error message occurs
again, contact your Sony service representative.
Approximate color