D-Link xStack DGS-3426G User Manual page 209

Layer 2+ gigabit ethernet managed switch
Table of Contents

Advertisement

(0-FFFFF)
Source IPv6
Address
Destination IPv6
Address
Port
Rx Rate (1-156249)
Time Range
Counter
To view the settings of a previously correctly configured rule, click
window:
The following window is the Access Rule table for Packet Content.
®
xStack
DGS-3426G Layer 2 Gigabit Ethernet Managed Switch
IPv6 header. This flow label field is used by a source to label sequences of packets such as
non-default quality of service or real time service packets.
The user may specify an IP address mask for the source IPv6 address by entering the IP
address mask, in hex form.
The user may specify an IP address mask for the destination IPv6 address by and entering the
IP address mask, in hex form.
The Access Rule may be configured on a per-port basis by entering the port number of the
switch in the switch stack into this field. When a range of ports is to be configured, the Auto
Assign check box MUST be clicked in the Access ID field of this window. If not, the user will be
presented with an error message and the access rule will not be configured. The port list is
specified by listing the lowest switch number and the beginning port number on that switch,
separated by a colon. Then the highest switch number and the highest port number of the
range (also separated by a colon) are specified. The beginning and end of the port list range
are separated by a dash. For example, 1:3 specifies switch number 1, port 3. 2:4 specifies
switch number 2, port 4. 1:3 - 2:4 specifies all of the ports between switch 1, port 3 and switch
2, port 4 − in numerical order. Entering all will denote all ports on the Switch.
Use this to limit Rx bandwidth for the profile being configured. This rate is implemented using
the following equation: 1 value = 64kbit/sec. (ex. If the user selects an Rx rate of 10 then the
ingress rate is 640kbit/sec.) The user many select a value between 1- 156249 or No Limit. The
default setting is No Limit.
Click the check box and enter the name of the Time Range settings that has been previously
configured in the Time Range Settings window. This will set specific times when this access
rule will be implemented on the Switch.
Tick the check box and use the drop-down menu to employ the Counter that will count the
packets identified with this rule. Users must note that if the Counter is employed in the ACL
Flow Meter function, the Counter will automatically be disabled here, regardless of this setting.
Figure 5 - 19 Access Rule Display window (IPv6)
in the Access Rule Table window to view the following
198