Engine Rpm Sensor - APRILIA RS4 125 Service Station Manual

Hide thumbs Also See for RS4 125:
Table of Contents

Advertisement

Electrical system
Maximum output voltage - high level: Vdc of the
pull-up resistance
Operating temperature range: -20÷60 °C (-4 °F÷
140 °F)
Function
To indicate the vehicle speed by reading the front
wheel turning speed.
Operation / Operating principle
Magnetoresistive sensor: generation of a square
wave.
Pin-out:
A. Control unit power
B. Control unit ground
C. Signal
ELECTRICAL ERRORS
Sensor/vehicle speed signal P0500 - over maximum limit/ signal not valid.
Error cause
Faulty sensor or cabling, interference on the signal.
Troubleshooting
Disconnect the sensor connector.
Verify, with the key ON, the presence of voltage (5V) between PIN A and B of the control
unit side connector.
If no voltage is read verify the continuity of the cabling between the control unit side sensor
connector (PIN A, B and C) and the control unit connector itself (PIN 21, 15 and 28).
If the cabling is intact but still no voltage is read, verify the insulation from ground of PIN A
control unit side sensor connector.

Engine rpm sensor

Ohmic resistance normalised at a temperature of
20 °C (68 °F): 105-124 Ohm
ELE SYS - 114