Precor P80 Service Manual page 41

Console
Hide thumbs Also See for P80:
Table of Contents

Advertisement

Test
Equipment
Brake Test
AMT, RBK,
UBK, EFX
Battery Test
AMT, RBK,
UBK, EFX
SPM
AMT, EFX
RPM Test
RBK, UBK
Cross Ramp
EFX Only
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Description
Touch Brake Test, then Touch START.
1
Use the machine control paddle to change the resistance
2
up and down. The resistance changes will be displayed in
power bits.
Touch STOP to end the test. Touch
3
Test.
Touch Battery Test, and then Touch START.
1
The console will display the voltage of the battery.
2
Touch STOP to end the test. Touch
3
Test.
Touch SPM Test, and then START.
1
The console will display Pulse. The pulse is showing a
2
count of zero crossings from the generator. SPM shows a
software averaged version of pulse. An averaged pulse per
minute will display as Minimum and a Maximum pulse.
Touch STOP to end the test. Touch
3
Systems Tests.
Touch RPM Test, and then START.
1
The console will display Pulse. The pulse is showing a
2
count of zero crossings from the generator. RPM shows a
software averaged version of pulse.
Touch STOP to end the test. Touch
3
Systems Test.
Touch Cross Ramp Test, and then Touch START.
1
Use the machine control paddle to change the Cross
2
Ramp. The console will display the analog to digital (A/D)
and Glitches incline position number. Dynamic available
battery voltage to the lift system will be displayed.
Touch STOP to end the test. Touch
3
Test.
BACK to Systems
BACK to Systems
BACK to exit to
BACK to exit to
BACK to Systems
Page 39