P80 System Test Menu Table
Test
Equipment
Auto Stop Test
TRM Only
Belt Speed Test
TRM Only
Incline Test
TRM,
Open Stride
AMT
AMT Stride
Position Test
AMT Only
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Description
Touch Auto Stop Test, then Touch START.
1
The Auto stop test will start the belt at 1 mph; count will be
2
reset to 0, and then count up with each step.
Touch STOP to end the test. Touch
3
Systems Test.
Touch Belt Speed Test, then Touch START.
1
The belt will start a 0.5 mph, using the machine control
2
paddle to increase by 0.1 mph increments. The console will
display motor current as the belt speed increases or
decreases.
Touch STOP to end the test. Touch
3
Systems Test.
Touch Incline Test, and then Touch START.
1
Use the machine control paddle to change the lift. The
2
console will display the analog to digital (A/D) incline
position number, the incline position in percent of incline,
and the Glitch incline position.
Touch STOP to end the test. Touch
3
Systems Test.
Touch AMT Stride Position Test and then Touch START.
1
The High, Low and Dynamic positions will be displayed.
2
The low position display shows the lowest position reading
achieved during the test. The high position display shows
the highest position reading achieved during the test. The
dynamic position display changes with current stride
position. At maximum stride length the low stride display
should read 0 and the high stride display should read 40.
Touch STOP to end the test. Touch
3
System Tests.
BACK to exit to
BACK to exit to
BACK to exit to
BACK to exit to