The PCA's in the console are static sensitive. They can be damaged if proper static prevention
2
equipment is not used. Attach an anti-static wrist strap to your arm, and then connect the ground lead
of the wrist strap to frame ground.
The HR PCA snaps into its mounting. Press the release tab sideways and remove the HR PCA from its
3
mounting.
Disconnect the HR cable and handlebar cable from the HR PCA.
4
Connect the HHHR Grip cable assembly to the upper connector on the HR PCA and the HR PCA
5
Power cable to the lower connector on the replacement HR PCA.
Orient the replacement HR PCA so that the side with the protective foam pad is facing out and snap
6
the HR PCA into its mounting.
Replace the rear vent cover.
7
Check operation per procedure,
8