  • Page 1 ENGLISH Personal Viewing System (PVS) Installation Guide for the P31 Console...
  • Page 2: Edition Information

    All rights, title, and interests in and to the software of the Preva Business Suite, the accompanying printed materials, any copies of such software, and all data collected via the Preva Business Suite, are exclusively owned by Precor or its suppliers, as the case may be.
  • Page 3: Installation Requirements

    Begin Assembly of the PVS To attach the PVS to the console, you need to reroute several cables. Hardware Hardware name Quantity PVS monitor IMPORTANT Assemble the equipment according to the guidelines in this manual to ensure that you do not void the Precor Limited Warranty. Any damage caused during installation is not covered by the Precor Limited Warranty.
  • Page 4 Hardware Hardware name Quantity Tie wrap Jack panel (treadmills only) Charging cable Ground wire Television (coax) cable with 90 degree elbow adapter PVS power cable AC power cord (based on region)
  • Page 5 Rewire the Equipment You must rewire the equipment to support the PVS functionality. This section Before you begin to rewire, remove the screws that secure the console in place. contains procedures to rewire the following equipment to accommodate a PVS: NOTE •...
  • Page 6 Rewire the Treadmill To thread the PVS power and television cables through the treadmill, refer to the following table and figure: Step Procedure Remove the console back cover, then the top cover on the upright support. Remove the hood and blank panel.
  • Page 7 Rewire the 800/600 EFX Step Procedure On the center column, lift the moisture seal upward and remove it. Remove the front top cap from the center column. To remove the bottle holder, strike the plastic parts of either side (see grey circle in graphic) with the heel of your palms.
  • Page 8 Rewire the 700 EFX Step Procedure Remove the bottom front cover. Using fish tape, thread the cables down the center column to the bottom. Remove the two screws that secure the blank jack plate on the front bottom cover. Attach the following cables to both sides of the new jack plate: A Communication cable B Television (coax) C Power cable...
  • Page 9 Note Each side cover has a small triangular mark to show you where to press. Thread the PVS power and television cables through the center column and guide them through the opening at the bottom. Important The cables must be secured in the cable retainers attached to the frame.
  • Page 10 Rewire the Recumbent Bike Remove the front and side access covers to provide sufficient space to install the console cables. NOTE You need to remove only one side cover to thread the cables. To thread the new cables through the equipment: Step Procedure Remove the top cover.
  • Page 11 Rewire the Upright Bike NOTE You need to remove only one side cover to thread the cables. To thread the new cables through the equipment: Step Procedure Use a #2 Phillips screwdriver to remove the two self-tapping screws holding the rear cover in place. Pull the upright rear cover back to remove it.
  • Page 12 Rewire the Climber To thread the PVS power and television cables through the climber, refer to the following figure and table: Step Procedure Push the rear tab in on the plastic top cover to unlock it before lifting it. You may need to detach the rubber grommet from the plastic top cover before sliding both along the upright column.
  • Page 13 • If the console is attached to the equipment, remove the four console mounting screws that hold it in place and set them aside. Place two screws into the PVS mounting bracket to align the holes with the bottom plate, and then fully tighten the back plate screw.
  • Page 14 IMPORTANT Data cable (Lower PCA) from the base unit DO NOT stretch, crimp, or damage the cable. Cables damaged by improper installation will not be covered by the Precor Limited Warranty. CSAFE To route the cables: Safety (Stop) key (treadmill only) Tip the console forward and hold it in place.
  • Page 15 Plug the cables into the chin circuit board Attach the ground wire using a tooth lock screw. Feed the USB charging cable from the top of the console. Use the following procedure to replace the current console chin with the device A Thread it behind the metrics board.
  • Page 16 Press the tab to remove the top cover from the new chin. See image for tab location. The audio cable plugs into the chin board and then routes to the PVS. To route the audio cable through the console: Remove the existing chin from the console.
  • Page 17 If the coax cable has a 90 degree fitting on it, remove the fitting before threading the cable up the mounting bracket. Hold the console still and move the PVS bracket side to side (see arrows in figure below) so that it is centered in the top opening of the console access cover.
  • Page 18 Attach the PVS to the mounting bracket Place the PVS bracket cover over the back of the PVS and secure it using four black screws. IMPORTANT At least two people are required to assemble the equipment. To complete PVS assembly: Remove the tape from the cables you threaded up the PVS mounting bracket.
  • Page 19: Maintenance

    If the equipment uses an optional power adapter, disconnect the adapter. Cleaning the PVS Screen Precor recommends that you clean the PVS at least one time per day. To remove dust and dirt from the PVS: • Use a clean, soft, lint-free cloth moistened with isopropyl alcohol solution to remove dust, dirt, and fingerprints from the screen surface.