Windhager DuoWIN Assembly Instructions Manual page 45

Wood/pellets
Table of Contents

Advertisement

2.
For the Installer
only for with automatic pellet feed:
– Connect the suction turbine plug – Fig. 95.
– Remove 3 screws from the front of the control panel cover. Pull out the cable plus grommet from the InfoWIN.
Raise and push the cover backwards, then remove it – Fig. 96.
– Connect the upper proximity switch on the integral fuel hopper to X22 plug – Fig. 97.
only for with manual pellet feed:
– Remove 3 screws at front of cover from the control panel, and pull out the cable plus grommet from the Info-
WIN. Raise and push the cover backwards, then remove it – Fig. 96.
– Connect the provided plug with bridge to the PCB X22 (3-pin) and to the suction turbine power plug (6-pin) –
Fig. 98.
Switch X22
mains power
plug suction
turbine
Fig. 95 Connect suction turbine power plug
Fig. 97 Connect proximity switch
Fig. 96 Remove cover from control panel
Switch X22
Fig. 98 Only for with manual pellet feed: Connect the
provided plug with bridge to the PCB X22 (3-
pin) and to the suction turbine power plug
45