Wall-Mounted Type - Sanyo SPW-C256VH Technical Data & Service Manual

4-way air discharge semi-concealed wall-mounted ceiling-mounted concealed-duct
Table of Contents

Advertisement

1
1-3. Other Component Specifi cations
Wall-Mounted Type SPW-KR124 – 254GH56 (A/B)
MODEL No.
Power Transformer
Rated
Source
Secondary
Coil resistance
Thermal cut off temperature
Thermistor (Coil sensor): TH
Resistance
Thermistor (Coil sensor):
Resistance
Electronic expansion valve
Valve body
Coil
Drain pump
Rated
Float switch
Rated (Contact rated)
Indoor Unit
VAC, Hz
Ω
°C
1-264
SPW-KR124 – 254GH56 (A/B)
ATR-IIK245
AC 230 V , 50/60 Hz
S1: 11 V, 1.25 A
S3: 20 V, 0.2 A
150°C
PBC-41E-AS7-1, PBC-41E-AS7-3
–10°C: 23.7±5%
–5°C: 18.8±5%
0°C: 15.0±5%
5°C: 12.1±5%
10°C:
9.7±5%
KTEC-35-S
0°C: 16.5±5%
5°C: 12.8±5%
10°C: 10.0±5%
20°C:
6.3±5%
30°C:
4.0±5%
S2: 14 V, 0.45 A
20°C:
6.5±5%
30°C:
4.4±5%
40°C:
3.1±5%
45°C:
2.6±5%
50°C:
2.1±5%
40°C:
2.7±5%
45°C:
2.2±5%
50°C:
1.8±5%
55°C:
1.5±5%