B) Outdoor Units - Sanyo SPW-C256VH Technical Data & Service Manual

4-way air discharge semi-concealed wall-mounted ceiling-mounted concealed-duct
Table of Contents

Advertisement

1-2. Major Component Specifi cations

(B) Outdoor Units

SPW-C256VH
MODEL No.
Source
Controller P.C.B. Ass'y
Control circuit fuse
Compressor
Model....number
Source
Nominal output
Compressor oil
Coil resistance
(Ambient temperature 25°C)
Safety control
Overload relay models
Operation temperature
Crank case heater
Refrigerant amount at shipment
High pressure switch
Set pressure
Fan
Number...diameter
Air circulation
Fan speeds (Max.)
Fan motor
Model No.
Source
No. of pole
Nominal output
Heat exchanger
Coil
Rows...fin pitch
Face area
W
cc
Ω
Excessive current control, Discharge temperature control
Open °C
Close °C
kg
2
OFF
kg / cm
2
ON
kg / cm
mm
3
m
/ h
W
mm
2
m
1-255
SPW-C256VH
220-230-240V, 1 phase, 50/60Hz
CR-C256VH (Microprocessor)
250V, 25A
C-6RVN103H0S
124V (DC) / 3phase / 60Hz (Inverter drive)
1,500
600
C – R : 0.452
C – S : 0.452
R410A - 1.7
1...ø420
2,220
~1,000 rpm (Inverter drive control)
DAJ12-55Q71-CR
~280V / 3 phase
8
60
Aluminium plate fin / Copper tube
2...1.3
0.452
1
R – S : 0.452

Hide quick links: