DC Fan Tap Change Procedure

<Procedure>
Be sure to turn the main power OFF before performing the steps below.
(1) Check the optional product that will be used from the table below.
Setting No.
Super long-life filter
[1]
Oil guard panel
Ammonia deodorizing filter
Optical regeneration deodorizing filter
High-performance filter, colorimetric 65% type
High-performance filter, colorimetric 90% type
[3]
Air cleaning unit
Deodorant filter
Air-blocking material (for 3-direction discharge)
Air-blocking material (when a discharge duct is connected) INS-DS140A
[6]
Air-blocking material (for 2-direction discharge)
Setting No.
: Go to (2).
[1]
Setting No.
: Go to (3).
[3]
Setting No.
: Go to (4).
[6]
(2) Setting No. [1]
Open the cover of the electrical component box, and connect the supplied short-circuit connector (2P, yellow) to
short-circuit pin TP1 (2P, red) on the indoor unit control PCB.
(3) Setting No. [3]
Open the cover of the electrical component box, and connect the supplied short-circuit connector (2P, yellow) to
short-circuit pin TP3 (2P, yellow) on the indoor unit control PCB.
(4) Setting No. [6]
Open the cover of the electrical component box, and connect the supplied short-circuit connector (2P, yellow) to
short-circuit pin TP6 (2P, white) on the indoor unit control PCB.