Omron CJ2 User Manual page 88

Cj series
Hide thumbs Also See for CJ2:
Table of Contents

Advertisement

3 Nomenclature and Functions
The MS and NS indicators can be green or red. The COMM, 100M, and 10M indicators are yellow.
These indicators can be lit, flashing, or not lit. The following table shows the meaning of these indi-
cator conditions.
Refer to SECTION 6 Troubleshooting for details on using these indicators for troubleshooting.
Indica-
Name
tor
MS
Module Status
NS
Network Sta-
tus
COMM
Communica-
tion
100 M
100 Mbps
10 M
10 Mbps
Seven-segment Display
EIP 21
When the power supply to the PLC is turned ON or the CPU Unit is reset, all of the segments will
flash twice, and then the IP address set for the built-in EtherNet/IP port will be displayed on the 7-
segment display from right to left. After the entire IP address is displayed, the lower 8 bits of the IP
address (node address) will be displayed in hexadecimal.
3-8
Color
Status
Red
Lit
Fatal error
Flashing Recoverable error
Green
Lit
Normal
---
Not lit
Power supply OFF
Red
Lit
Fatal error
Flashing Recoverable error
Green
Lit
Tag data link and message connections established
Flashing Tag data link and message connections not established
---
Not lit
Offline or power supply OFF
Yellow
Lit
Transferring data
Not lit
Not transferring data
Yellow
Lit
100Base-TX link established
Not lit
100Base-TX link not established
Yellow
Lit
10Base-TX link established
Not lit
10Base-TX link not established
Meaning
CJ2 CPU Unit Hardware User's Manual