Omron CJ2 User Manual page 46

Cj series
Hide thumbs Also See for CJ2:
Table of Contents

Advertisement

1 Overview
Items
Programming Languages
Function
Maximum number of definitions
Blocks
Maximum number of instances
Tasks
Type of Tasks
Number of Tasks
Symbols (Vari-
Type of Symbols
ables)
Data Type of Symbols
Maximum Size of Symbol
Array Symbols (Array Variables)
Number of Array Elements
Number of Registrable Tags
Length of Tag Name
Encode of Tag Name
Data Tracing
Memory Capacity
Number of Samplings
Sampling Cycle
Trigger Conditions
Delay Value
File Memory
Source/Com-
Function block program memory,
ment Memory
comment file, program index file,
symbol tables
1-10
CPU64-EIP
CPU65-EIP
Ladder Logic (LD),
Sequential Function Charts (SFC),
Structured Text (ST), and
Instruction Lists (IL)
2,048
2,048
Cyclic tasks
Interrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I/O interrupt tasks, and external
interrupt tasks)
Cyclic tasks: 128
Interrupt tasks: 256
(Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of
cyclic tasks is actually 384 max.)
• Local symbols: Can be used only within a single task in the PLC.
• Global symbols: Can be used in all tasks in the PLC.
• Network symbols (tags): I/O memory in the CPU Unit can be externally accessed using symbols,
depending on parameter settings.
• BOOL (bit)
• UINT (one-word unsigned binary)
• UDINT (two-word unsigned binary)
• ULINT (four-word unsigned binary)
• UINT BCD (one-word unsigned BCD)
• INT (one-word signed binary)
• DINT (two-word signed binary)
• LINT (four-word signed binary)
• UDINT BCD (two-word unsigned BCD)
• ULINT BCD (four-word unsigned BCD)
• REAL (two-word floating-point), LREAL (four-word floating-point)
• CHANNEL (word), NUMBER (constant or number)
• WORD (one-word hexadecimal)
• DWORD (two-word hexadecimal)
• LWORD (four-word hexadecimal)
• TIMER
• COUNTER
32k words
One-dimensional arrays
32,000 elements max.
20,000 max.
255 bytes max.
UTF-8
8,000 words
(Up to 32k words x 25 banks when EM is specified in CX-Programmer)
Bits = 31, one-word data =16, two-word data = 8, four-word data = 4
1 to 2,550 ms (Unit: 1 ms)
ON/OFF of specified bit
Data comparison of specified word
Data size: 1 word, 2 words, 4 words
Comparison Method: Equals (=), Greater Than (>), Greater Than or Equals (3), Less Than (<), Less
Than or Equals (≤), Not Equal (≠)
−32,768 to +32,767 ms
Memory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.)
EM file memory (Part of the EM Area can be converted for use as file memory.)
Capacity: 3.5 Mbytes
CJ2H-
CPU66-EIP
CPU67-EIP
16,000 words
32,000 words
CJ2 CPU Unit Hardware User's Manual
CPU68-EIP