• Inverter should pass human body safety test.
• Inverter should no smoking by any component open / short test
• Transformer voltage stress should not be over 85% under any condition (turn
on overshoot transient and line transient).
• Audio noise should be less than 36dB at 10 cm distance.
4.4

Electrical specification

4.4.1 Electrical specification
No
Symbol
V
.
oper
I
L
I
L
1
I
L
I
L
f
η
4.4.2 Thermal
All components on inverter board should follow below rules:
• Component using conditions (component stress) must be within component
specification including voltage rating, current rating, temperature etc.
• Component temperature should follow below:
Δ T < 30°C, at 25, 35°C.
Component temperature should be less than 70 ° C inside system at 35 ° C.
4.5

Connector description

4.5.1 Input Connector:
CN1: ACES 87213-0700; JST SM07B-SRSS-TB
1
2
3
4
Min.
Type.
Max.
--
650
6.2
6.5
3.0
3.3
5.7
6
2.7
3
45
55
80%
--
Symbol
INV_PWR
INV_PWR
INV_PWM
DISOFF #
Unit
--
Vrms
Lamp operating voltage (650+/-50)
6.8
mArms
3.6
mArms
6.3
mArms
3.3
mArms
65
KHz
--
--
Input voltage (9V-21V)
Input voltage (9V-21V)
Adjust brightness by burst mode (3.3 V 150Hz)
Backlight on/off control, active HIGH (3.3V)
JHT01 Service Manual
Comment
DAC_BRIG: 0 V, PWM: 100%
DAC_BRIG: 0 V, PWM: 30%
DAC_BRIG: 1 V, PWM: 100%
DAC_BRIG: 1 V, PWM: 30%