Overheat (OH)/Fan Fail LED

Connect an LED cable to pins 7 and 8
of JF1 to provide advanced warnings
of chassis overheating and fan failure.
Refer to the table on the right for pin
definitions.

Power Fail LED

The Power Fail LED connection is
located on pins 5 and 6 of JF1. Re-
fer to the table on the right for pin
definitions.
JPL2
JHD_AC1
BIOS
Battery
S-SATA3
BT1
S-SATA2
S-SATA1
PCH
S-SATA0
JSD2
I-SATA3
I-SATA2
I-SATA1
I-SATA0
JL1
JSTBY1
JF1
LEDPWR
USB5/6
(3.0)
USB3/4
(3.0)
FAN6
J21
JPI2C1
HD AUDIO
LAN2
LAN1
X10DAL-i
FAN5
Rev. 1.02
CPU2
CPU1
2-23
OH/Fan Fail/PWR Fail LED
Pin Definitions (JF1)
Pin #
Definition
7
Vcc
8
OH/Fan Fail LED)
OH/Fan Fail Indicator
Status
State
Definition
Off
Normal
On
Overheat
Flash-
Fan Fail
ing
PWR Fail LED
Pin Definitions (JF1)
Pin #
Definition
5
3.3V
6
PWR Supply Fail
A. OH/Fail Fail LED
B. PWR Supply Fail
Ground
X
Power LED
HDD LED
NIC1 LED
NIC2 LED
A
OH/Fan Fail LED
B
PWR Fail LED
JPWR2
Ground
JPWR1
Ground
Chapter 2: Installation
20
19
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset