The software "RF-MANAGER"
8.3 Application mode "Mobile"
Figure 8-10
In the "Mask" line, you can select the following transponder-specific memory areas:
● "Kill": Kill Password
● "Acc": Access Password For memory areas EPC, TID and user memory
● "EPC": EPC memory
● "TID": TID memory
● "Usr": User memory
"Lock"
The entries under "Mask" determine which function is executed in the action area.
0
1
Line
Mask
Action
The entry in the "Action" line specifies how the associated memory area will be locked.
● The identifier "r/w" defines password protection for reading/writing
● The identifier "w" defines password protection for writing (reading is permitted)
● The identifier "p" specifies permanent locking
All the possible combinations of "r/w", "w" and "p" are listed in the table below complete with
their significance for the different memory areas.
46
Lock Tag
The action will not be executed
The action will be executed
Kill PWD
Access PWD
0/1
0/1
r/w
p
EPC memory
0/1
0/1
0/1
r/w
p
w
Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618
TID memory
0/1
0/1
0/1
p
w
p
SIMATIC RF680M Mobile Reader
User memory
0/1
0/1
w
p