Siemens SIMATIC RF680M Operating Instructions Manual page 38

Mobile reader simatic rf680m
Hide thumbs Also See for SIMATIC RF680M:
Table of Contents

Advertisement

The software "RF-MANAGER"
8.3 Application mode "Mobile"
The "current area"
Current area
Memory area ISO 18000-6C (EPC Class1 Gen2)
● USER:
● EPC:
36
User data area. Freely available
its size or presence is specific to the manufacturer.
Memory area in which the tag ID is stored.
The area is read-only.
Description
When "Total" is not checked, the area is displayed that is specified
in the fields "Address" and "Length".
You can reach the individual addresses using the input pen. If you
change the values, they will have a green background. The green
background remains until the data are transferred/written to the
transponder. The color green therefore indicates that the actual tag
data differs from the values visible in the editor.
All other data areas of the tag are shown against a white
background.
30112233445566778899AAC0)
Operating Instructions, 06/2011, J31069-D0241-U001-A2-7618
PC: 2 bytes of Protocol Control bits
EPC: 12 bytes tag ID (in this example:
CRC: 2 bytes of check sums
SIMATIC RF680M Mobile Reader