Setgbicmode; Supportshow - IBM TotalStorage 300 Service Manual

Model 325
Hide thumbs Also See for TotalStorage 300:
Table of Contents

Advertisement

setGbicMode

The GBIC mode, when enabled, forces crossPortTest or spinSilk to limit its testing
to only those ports whose GBICs or imbedded optics are detected present.
To enable GBIC mode execute:
switch:admin> setGbicMode 1
To disable GBIC mode execute:
switch:admin> setGbicMode 0

supportShow

The supportShow command prints the Fibre Channel hub's information for
debugging purposes. supportShow executes the following commands in the order
shown:
version
tempShow
psShow
licenseShow
diagShow
errDump
switchShow
portFlagsShow
portErrShow
mqShow
portSemShow
portShow
portRegShow
portRouteShow
fabricShow
topologyShow
154
IBM NAS 300 Service Guide
Table 27. diagShow command field descriptions
Field
Diagnostics status
port#
diags
state
lm0-7 (8-port) 1m0-15 (16-port)
Central memory status
Total diag frames Tx
Total diag frames Rx
Description
The title header displays the time diagShow
was executed.
The port number.
diagsCurrent diagnostic status of the port.
Possible values include OK, BAD.
Current state of the port. Possible values
include UP (active), DN (inactive).
The frame counts of active ports. The display
shows the number of frames transmitted and
received and low level interface counts
(LLI_errs).
Central memory status. Possible values
include OK, FAULTY.
The total diagnostics frames transmitted (Tx)
since start up. This number usually
corresponds to the total frames received (Rx)
but may differ because of failure modes.
The total diagnostics frames received (Rx)
since start up. This number usually
corresponds to the total frames transmitted
(Tx) but may differ because of failure modes.