NEC SigmaBlade N8406-040(F) User Manual page 177

8g fc switch
Table of Contents

Advertisement

NOTE:
Confirm that all created zones appear by using the "zonecreate" command.
After a zone name, ports contained in the zone appear. Confirm that the specified ports
appear normally.
WWN mode zoning
For WWN mode zoning, use WWPn's of the fibre channel devices connected to the 8G FC Switch
to set the zoning.
1) Checking WWPn
Check WWPn's of the fibre channel devices to be used.
1.
NOTE:
For how to check WWPn's of fibre channel devices to be used, refer to the User's
Guides attached to the devices.
2) Creating zone
Use the "zonecreate" command to create a zone.
Use of "zonecreate" command
zonecreate
(1) zonename:
Specify the created zone name with it enclosed by double quotation marks (").
(2) member:
Specify WWPn of a fibre channel device.
NOTE:
Delimit the zone name and the first WWPn with a comma (,).
Delimit adjacent WWPn specifications with a semicolon (;).
Use the "zonecreate" command on the console screen to create zones.
2.
ALE044120T2:admin> zonecreate "zone1","10:00:00:00:c9:4b:a1:e5;20:01:00:30:13:84:03:d2"
ALE044120T2:admin> zonecreate "zone2","10:00:00:00:c9:4b:a2:05;20:02:00:30:13:84:03:d2"
ALE044120T2:admin> zonecreate "zone3","10:00:00:00:c9:4b:a1:f6;20:05:00:30:13:84:03:d2"
ALE044120T2:admin> zonecreate "zone4","10:00:00:00:c9:4b:83:aa;20:06:00:30:13:84:03:d2"
ALE044120T2:admin>
NOTE:
Any commands used on the switch console should be specified with lowercase letters.
IMPORTANT:
A zone name can be up to 64 alphanumeric characters.
This command must be done by the number of zones to be created.
Type "zoneshow" command on the console screen.
3.
"zonename" ,
"member;member;member"
(1)
(2)
- 177 -