Changing Isl R_Rdy Mode - NEC SigmaBlade N8406-040(F) User Manual

8g fc switch
Table of Contents

Advertisement

Changing to G_Port fixing
Releasing G_Port fixing

Changing ISL R_RDY Mode

After completing login to the console of the 8G FC Switch, change the ISL R_RDY Mode of each
ports cascaded with other switchs on the 8G FC Switch according to the procedure below. (The
port topology must always be set.)
Setting at shipment from factory
The ISL R_RDY Mode is Disabled for every port when the 8G FC Switch is shipped from the
factory.
IMPORTANT:
Also port to connect to a switch of the cascade connection, please set to "Enable" the
ISL R_RDY Mode.
For ports that are NOT cascaded with other switches, please remain "Disable" the ISL R_RDY
Mode.
Change the setting of ISL R_RDY Mode, please be performed at the timing when not using the
port.
Type "portcfgshow" command on the console screen.
1.
NOTE:
Any commands used on the switch console should be specified with lowercase letters.
The current port settings appear.
2.
IMPORTANT:
The port status display also includes the information on the ports unavailable to
N8406-040. However, this is not an error.
Change the ISL R_RDY Mode.
3.
Type "portcfgislmodet x y" to change the ISL R_RDY Mode on port.
Value "x" is the number of the port whose topology is to be changed.
Value "y" shows whether fixing the port topology to be set is enabled or disabled.
After the setting is changed completely, type "portcfgshow" command.
4.
Check if the new setting resulting from the change is made effective. The setting is completed if the
information on each changed port appears as shown below.
External ports available to N8406-040: 17 - 20
External ports available to N8406-042: 17 - 23 and 0
0 = Disable or 1 = Enable
Information on Lockd G_Port
ON
··