Chapter 4 Powering on Switch for the First Time

4.1 Establish configuration environment

Setting up the configuration environment (the following figure is as reference):
Terminal (a PC in this example) is connected to the Console port of the switch
through a Console cable.
PC
PC
Figure 4-1 Configuration networking when powering on the switch for the first time

4.2 Connecting the Console Cable

Step 1: Plug the DB-9 or DB-25 female connector of Console cable to the serial port
of the PC where the switch is to be configured.
Step 2: Connect the RJ-45 connector of Console cable to the Console port of the
switch.

4.3 Setting Terminal Parameters

Step 1: Start the PC and run the terminal emulation program such as the Terminal of
Windows3.1 or the Hyper Terminal of Windows95/98/NT.
Step 2: Set terminal parameters (For example, set the hyper terminal parameters in
Windows98).
Parameter requirements: Set baud rate to 9600, data bit to 8, parity to none, stop bit
to 1 and flow control to none. Select VT100 as terminal emulation. The specific
means are as follows:
Connect to the Console port
Connect to the Console port
Connect to the serial port
Connect to the serial port
Console cable
Console cable
Chapter 4 Powering on Switch for the First Time
Switch
Switch
4-1