7.2 Regulations Covering Insert Installation

When installed and operated as described in these instructions, the Destination 1.5 wood insert is
suitable for use in residential installations. The Destination 1.5 wood insert is not intended for
installation in a bedroom.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and
the CSA C22.1 Canadian National Electrical Code are to be followed in the absence of local code
requirements. In the USA, the ANSI NFPA 211 Standard for Chimneys, Fireplaces, Vents and
Solid Fuel-Burning Appliances and the ANSI NFPA 70 National Electrical Code are to be followed
in the absence of local code requirements.
This insert must be installed with a continuous chimney liner of 6" diameter extending from the
insert to the top of the chimney. The chimney liner must conform to the Class 3 requirements of
CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-built Chimneys and
Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.
NOTE: The Insert is not approved for use with a so-called "positive flue connection" to the clay
tile of a masonry chimney.

8 Clearances to Combustible Material

The clearances shown in this section have been determined by test according to procedures set
out in safety standards ULC S628 (Canada) and UL1482 (U.S.A.). When the insert is installed so
that its surfaces are at or beyond the minimum clearances specified, combustible surfaces will not
overheat under normal and even abnormal operating conditions.
No part of the insert may be located closer to combustibles than the minimum clearance
figures given.

8.1 Location of the Certification Label

Since the information given on the certification label attached to the appliance always overrides the
information published in any other media (owner's manual, catalogues, flyers, magazines and/or
web sites), it is important to refer to it in order to have a safe and compliant installation. In addition,
you will find information about your insert (model, serial number, etc.). The certification label can be
reached by following these steps:
1. Open the loading door.
2. On the left side of the appliance,
unfasten the screw (B) holding the
certification label plate (A) place.
30