Alcatel-Lucent OmniSwitch 6850E Series Hardware User's Manual page 85

Hide thumbs Also See for OmniSwitch 6850E Series:
Table of Contents

Advertisement

OmniSwitch 6850E Series Power Supplies
4 Tighten the clamp by tightening the screw above the slot into which you inserted the wire lead. The
wire lead should be securely attached inside the connector. You should be able to pull on the wire and not
dislodge it.
Warning. For DC input voltages, the positive (+) wire of the sourcing equipment, such as a battery or
rectifier, must be connected to the positive (+) terminal of the OmniSwitch DC power supply and the
negative (-) wire of the sourcing equipment must be connected to the negative (-) terminal of the
OmniSwitch DC power supply."
5 Repeat Steps 2 through 4 for the remaining positive and negative wire leads.
OS6850E Power Sup-
OmniSwitch 6850E Series Hardware Users Guide
Correct Polarity Connections
January 2013
OmniSwitch 6850E Series Power Supplies
DC Power Source
page 3-17