Link Oam Pdu - Alcatel-Lucent OmniSwitch 6850E Series Hardware User's Manual

Hide thumbs Also See for OmniSwitch 6850E Series:
Table of Contents

Advertisement

OmniSwitch 6850E Series Chassis and Hardware Components

Link OAM PDU

As soon as the power failure is detected an 802.3ah OAM Information PDU is sent to all ports for which
link OAM is enabled and the LinkOAM port status is operational. The PDU will have the Dying Gasp bit
set.
Use the
and
efm-oam
802.3ah OAM Information PDU upon a dying gasp event:
-> efm-oam enable
-> efm-oam port 2/1-10 propagate-events dying-gasp enable
Link OAM PDU Priority
It may not be possible to generate PDUs on all ports enabled for link OAM. Dying gasp packets will be
sent in the following order based on port priority:
1. Uplink ports
2. Combo ports
3. All other ports
OmniSwitch 6850E Series Hardware Users Guide
efm-oam port propagate-events
January 2013
commands to enable the generation of an
Dying Gasp
page 2-49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents