Effectivity: 912 i Series
OM Edition 1/Rev. 2
Step
Designation
NOTICE
10
Starter Switch
NOTICE
11
Throttle valve
12
Engine instruments
NOTICE
13
Throttle valve
NOTICE
14
Engine instruments
BRP-Powertrain
Procedure
For more and detailed information on
the throttle opening during engine start
up see the diagram.
See Fig. 3
Press until the engine runs
and release after engine has
reached 1500 rpm or more
(stable engine run).
Activate starter for maximum of 10 sec-
onds only (without interruption), fol-
lowed by a cooling period of 2
minutes.
Reduce throttle lever as re-
quired.
Check for error messages
and if all operator limits are
within the operator limits de-
fined in the Operators Manu-
al. Check if oil pressure has
risen within 10 seconds and
monitor oil pressure.
Increasing engine speed is only permit-
ted at steady oil pressure readings
above 3 bar.
Increase engine speed
above 2500 rpm and hold
speed at least 5 secounds
(await generator shift from
Gen B to Gen A).
If, after the engine start, a warning lamp
flashes or lights up, perform a LANE and
IGNITION check. After the LANE and
IGNITION check both warning lamps
must be deactivated, otherwise there is
an error that must be located and re-
paired before the next flight.
Check for error messages
and if all operator limits don't
exceed the operator limits de-
fined in the Operators Manu-
al. Check if generator
switching was realized
flawless.
page 3-9