Engine Shut-Off - Rotax 912 i series Operator's Manual

Hide thumbs Also See for 912 i series:
Table of Contents

Advertisement

3.9) Engine shut-off

General note
Effectivity: 912 i Series
OM Edition 1/Rev. 2
Normally the cooling down of the engine during descending and
taxiing will be sufficient to allow the ECU to be shut off as soon as
the aircraft is stopped.
At increased operating temperatures make an engine cooling run
of at least minimum 2 minutes.
Step
1
Check the engine instruments.
2
Reduce engine speed down to idling.
Set the LANE select switch B to "OFF".
3
Set the LANE select switch A to "OFF".
4
Switch the fuel pumps "OFF".
5
6
Shut-off according to the aircraft manufacturer regulations.
Set main switch to "OFF". Wait for engine stop.
7
BRP-Powertrain
Procedure
April 01/2014
page 3-14