1. Adjustment & Inspection Tools
(A) Color Analyzer
(C) Multi Meter
(E) Convergence Meter
(G) Power Meter
2.
Timing Table (Factory Mode –20 Modes)
MODE
RESOLUTION
1
VGA350
2
VGA400
3
VGA480
4
MACII35K
5
800*600(56)
6
8514A
7
640*480(75)
8
EVGA400
9
800*600(60)
10
640*480
11
800*600(75)
12
1024*768(60)
13
MACII 49K
14
800*600(85)
15
1024*768(70)
16
1024*768(75)
17
640*480(120)
18
1280*1024(60)
19
800*600(100)
20
1024*768(85)

3. Normal Condition Definition

(A) Input AC Voltage 110V/60Hz.
(B) Warm up time minimum 30 minutes.
(C) Full White Pattern.
(D) All VR's adjust to Center Position.
(F) Color temp 9300K
(B) Signal Generator CHROMA 2135 or compatible
(D) Hi-Voltage Probe
(F) Degaussing Probe
(H) Automatic Alignment system
H-SYNC EREQ. V-SYNC FREQ H . POLARITY V . POLARITY
31.5KHz
31.5KHz
31.5KHz
35.0KHz
35.2KHz
35.5KHz
37.5KHz
37.8KHz
37.8KHz
43.3KHz
46.8KHz
48.3KHz
49.7KHz
53.6KHz
56.4KHz
60.0KHz
63.7KHz
64.0KHz
64.0KHz
68.6KHz
70Hz
+
70Hz
-
60Hz
-
66Hz
-
56Hz
+
87Hz
+
75Hz
-
84Hz
-
60Hz
+
85Hz
-
75Hz
+
60Hz
-
74Hz
-
85Hz
+
70Hz
-
75Hz
+
120Hz
-
60Hz
+
100Hz
+
85Hz
+