Adjustment & Inspection Tools; Timing Table; Normal Condition Definition - Mitsubishi Diamond Plus 93SB Service Manual

Hide thumbs Also See for Diamond Plus 93SB:
Table of Contents

Advertisement

1. Adjustment & Inspection Tools
(A) Color Analyzer
(C) Multi Meter
(E) Convergence Meter
(G) Power Meter
2.
Timing Table (Factory Mode –18 Modes)
MODE
RESOLUTION
1
VGA400
2
VGA640*480
3
640*480(75)
4
640*480(85)
5
800*600(75)
6
MACII 49K
7
800*600(85)
8
1024*768(75)
9
1280*1024(60)
10
1024*768(85)
11
1280*1024(75)
12
1280*1024(85)
13
1600*1200(75)
14
1024*768(60)
15
800*600(60)
16
MACII 35K
17
MAC 1152*870
18
VGA720*400(70)

3. Normal Condition Definition

(A) Input AC Voltage 110V/60Hz.
(B) Warm up time minimum 30 minutes.
(C) Full White Pattern.
(D) All VR's adjust to Center Position.
(F) Color temp 9300K
(B) Signal Generator CHROMA 2235 or compatible
(D) Hi-Voltage Probe
(F) Degaussing Probe
H-SYNC EREQ. V-SYNC FREQ H . POLARITY V . POLARITY
31.4KHz
31.4KHz
37.5KHz
43.2KHz
46.8KHz
49.7KHz
53.6KHz
60.0KHz
64.0KHz
68.6KHz
79.9KHz
91.1KHz
93.7KHz
48.3KHz
37.8KHz
35.0KHz
68.7KHz
31.5KHz
70Hz
-
60Hz
-
75Hz
-
85Hz
-
75Hz
+
75Hz
-
85Hz
+
75Hz
+
60Hz
+
85Hz
+
75Hz
+
85Hz
+
75Hz
+
60Hz
-
60Hz
+
67Hz
-
75Hz
-
70Hz
-
4-2
+
-
-
-
+
-
+
+
+
+
+
+
+
-
+
+
-
+