3.4 Power Supply

Input Voltage
Frequency
Power Consumption (Max.)
AC leakage current
Inrush current

3.5 Power Saving

H-sync
ON Mode
On
Off
Off
Mode
On
Off

3.6 Degaussing

Auto Degaussing
Manual Degaussing
The Monitor requires minimum 15 minutes after last degauss operation for full degauss capability.
100 – 240 VAC ± 10%
50 - 60Hz ± 3Hz
70W 100 – 240VAC, 1.5A
Condition:
Input voltage:100 - 240VAC
Signal: No.13 (1024x768(85Hz), (All white))
Contrast: Max, Brightness: Max,
H/V size: full scan
Others: default position
(Typical)
65W @ 120VAC /60Hz
64W @ 230VAC /50Hz
Condition:
Signal: No.13 (1024x768(85Hz), (All white))
Contrast: Max, Brightness: Cutoff,
H/V size: preset
Others: default position
Except Japan ≤ 3.5mA (254V), Japan ≤ 0.2mA (100V)
≤ 42A 0-peak at 240VAC on cold starting
(or ≤ 30Arms(half cycle) at 240VAC on cold starting)
≤ 100A 0-peak at 240VAC on hot starting
(or ≤ 70Arms(half cycle) at 240VAC on hot starting)
V-sync
Video
On
Active
On
Blank
Off
Blank
Off
Blank
The monitor has an automatic degaussing function
which activates when the unit is turned on.
This activates degaussing at the user's discretion after
the unit is operating
Power
Consumption
70W (Max.)
≤ 5W
5-8
Recovery
LED
Time
Indicator
-
Green
3 - 5 sec